Background
The indication of additional aortic arch surgery for residual aortic dissection remains controversial as some patients experience aneurysm rupture at a smaller diameter of 55 mm.
Method
An 84-year-old woman, who underwent total arch replacement for chronic dissection, developed rupture of a residual aneurysm of with a diameter of 48 mm. Computational fluid dynamics simulated pressure and wall shear stress comparing pre- and post-total arch replacement.
Results
After total arch replacement, false lumen pressure in the distal aortic arch increased (pre, 138.5 mmHg; post, 148.2 mmHg). Wall shear stress also increased in the distal aortic arch (pre, 10.5 Pa; post, 16.9 Pa).
Conclusion
Computational fluid dynamics could retrospectively predict a significant postoperative increase in false lumen pressure and wall shear stress of chronic dissections after total arch replacement, potentially leading to aneurysm rupture.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.