Different models for estimation of the dead layer thickness at the ferroelectric film-metal interface are discussed, including the small-signal capacitance model and two methods based on dielectric hysteresis analysis-one based on slopes of the hysteresis loops at the coercive field and the other method based on comparison of dielectric hysteresis portraits. It is shown that the latter technique yields more reliable data as it excludes the effect of leakage and relaxation loss. Conductivity may have a pronounced effect on the validity of dead-layer thickness data. This work relates peripherally to negative capacitance in ferroelectric films and to lozenge-shaped hysteresis curves.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.