Proton pump inhibitors, including omeprazole, rabeprazole, lansoprazole, and pantoprazole, achieved simultaneous enantioselective determination in the human plasma by chiral liquid chromatography–tandem mass spectrometry. The four corresponding stable isotope‐labeled proton pump inhibitors were adopted as the internal standards. Each enantiomer and the internal standards were extracted with acetonitrile containing 0.1% ammonia, then separated with a Chiralpak IC column (5 µm, 4.6 mm × 150 mm) within 10 min. The mobile phase was composed of acetonitrile–ammonium acetate (10 mM) containing 0.2% acetic acid (50:50, v/v). To quantify all enantiomers, an API 4000 tandem mass spectrometer was used, and multiple reaction monitoring transitions were performed on m/z 360.1→242.1, 384.1→200.1, 370.1→252.1, and 346.1→198.1, respectively. No significant matrix effect was observed for all analytes. The calibration curve for all enantiomers were linear from 1.25 to 2500 ng/mL. The precisions for intra‐ and inter‐run were < 14.2%, and the accuracy fell in the interval of –5.3 to 8.1%. Stability of samples was confirmed under the storage and processing conditions. The developed method was also suitable for separation and determination of ilaprazole enantiomers. The validated method combining the equilibrium dialysis method was applied to the protein binding ratio studies of four pairs proton pump inhibitor enantiomers in human plasma.
Rabeprazole is an effective proton pump inhibitor to treat acid‐related diseases. To achieve the simultaneous determination of rabeprazole enantiomers in human plasma, a chiral LC‐MS/MS method was developed and validated. Acetonitrile including 0.1% ammonium were used as protein precipitating agent. Analytes were separated within 8 minutes on a Chiralpak IC column (4.6 mm × 150 mm, 5 μm). The mobile phase was 10 mM ammonium acetate including 0.2% acetic acid‐acetonitrile (35:65, v/v). An API 4000 mass spectrometer was used as detector for the analysis, and the multiple reactions monitoring transitions of m/z 360.1 → 242.2 and 346.1 → 198.1 were opted for quantifying rabeprazole enantiomers and internal standard. Matrix effects were not apparent for each enantiomer and internal standard (esomeprazole), the calibration curves were linear over the concentration of 0.500 to 400 ng·mL−1, the intra‐run precisions were below 5.4%, the inter‐run precisions were below 9.9%, and the accuracy was between −9.2% and 9.3%. There was no chiral inversion observed during sample storage, preparation procedure, and analysis, demonstrating that analytes were stable in this study. This method was applied to the stereoselective pharmacokinetic study of (R)‐(+)‐ and (S)‐(−)‐rabeprazole after oral administration of 10‐mg rabeprazole sodium enteric‐coated tablet in healthy Chinese subjects.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.