Tunnel magnetoresistive (TMR) devices have superior performances in weak magnetic field detection. In this study, TMR devices were first employed to form a circular magnetic flux leakage (MFL) sensor for slight wire rope flaw detection. Two versions of this tailor-made circular TMR-based sensor array were presented for the inspection of wire ropes with the diameters of 14 mm and 40 mm, respectively. Helmholtz-like coils or a ferrite magnet-based magnetizer was selected to provide the proper magnetic field, in order to meet the technical requirements of the TMR devices. The coefficient of variance in the flaw detection performance of the sensor array elements was experimentally estimated at 4.05%. Both versions of the MFL sensor array were able to detect multiple single-broken wire flaws in the wire ropes. The accurate axial and circumferential positions of these broken wire flaws were estimated from the MFL scanning image results. In addition, the proposed TMR-based sensor array was applied to detect the MFL signal induced by slight surface wear defects. A mutual correlation analysis method was used to distinguish the signals caused by the lift-off fluctuation from the MFL scanning image results. The MFL sensor arrays presented in this study provide inspiration for the designing of tailor-made TMR-based circular sensor arrays for cylindrical ferromagnetic structural inspections.
Assessing the effect of defect induced stresses on magnetic flux leakage (MFL) signals is a complicated task due to nonlinear magnetomechanical coupling. To facilitate the analysis, a multiphysics finite elemental simulation model is proposed based on magnetomechanical theory. The model works by quasi-statically computing the stress distribution in the specimen, which is then inherited to solve the nonlinear magnetic problem dynamically. The converged solution allows identification and extraction of the MFL signal induced by the defect along the sensor scanning line. Experiments are conducted on an AISI 1045 steel specimen, i.e. a dog-bone shaped rod with a cylindrical square-notch defect. The experiments confirm the validity of the proposed model that predicted a linear dependency of the peak-to-peak amplitude of the normalized MFL signal on applied stress. Besides identifying the effect of stress on the induced MFL signal, the proposed model is also suitable for solving the inverse problem of sizing the defects when stress is involved.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.