The bioavailability of 2 kinds of digoxin tablets (0.25mg) on the Japanese market was compared. Two tablets were given daily in empty stomach to 3 each of healthy men and women. Serum levels of digoxin were measured by radioimmunoassay before and 0.5, 1, 2, 4 and 6 hours after the administration.In vitro tests were performed to determine the weight variation, hardness, content, disintegration time and dissolution time of the tablets. As a result, some differences in the test items were found although they might be caused by additives in the tablets.There was no statistically significant difference in the serum level among the products because of the fact that the difference among the human subjects was larger than that among the products. Therefore, it can be said on the basis of the in vitro and in vivo tests that the two products are interchangeable.But the blood level of digoxin should occasionally be determined in patients under this therapy because of individual difference in bioavilability.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.