A new highly sensitive method of looking for electric dipole moments of charged particles in storage rings is described. The major systematic errors inherent in the method are addressed and ways to minimize them are suggested. It seems possible to measure the muon EDM to levels that test speculative theories beyond the standard model. PACS numbers: 13.40. Em, 12.60.Jv, 14.60.Ef, 29.20.Dh The existence of a permanent electric dipole moment (EDM) for an elementary particle would violate parity (P) and time reversal symmetry (T) [1]. Therefore under the assumption of CPT invariance, a non-zero EDM would signal CP violation. In the standard model, the electron EDM is < 10 −38 e · cm [2] with the muon EDM scaled up by the mass ratio m µ /m e , a factor of 207, but some new theories predict much larger values [3,4]. For example, ref.[4] predicts the muon EDM could be as large as 5 × 10 −23 e · cm, while the electron EDM is predicted to be ∼ 10 −28 e · cm, an order of magnitude below the present limit [5]. The current 95% confidence limit for the muon EDM is 10 −18 e·cm [6]. This paper discusses a new way of using a magnetic storage ring to measure the EDM of the muon, which also can be applied to other charged particles.To measure the EDM experimentally, the particle should be in an electric field which exerts a torque on the dipole and induces an observable precession of its spin. If the particle is charged this electric field inevitably accelerates the particle; it will move to a region where the field is zero or leave the scene. An example is the nucleus at the center of an atom in equilibrium; the net force and therefore the net electric field at the nucleus must average to zero according to Schiff's theorem [7]. Any applied external electric field will be shielded from the nucleus by the electrons in the atom. The overall effect is to suppress the EDM signal, making it more difficult to measure. The suppression would be total but for the many known exceptions to Schiff's theorem when weak and strong forces, weak electron-nucleon forces, finite particle sizes, and relativistic effects are included. Suppression of the EDM signal by Schiff's theorem is completely avoided in a magnetic storage ring [8,9] such as proposed here, because the particle is not in equilibrium; there is a net centripetal force, and this force is entirely supplied by a net electric field as seen in the muon rest frame.In particular, when a muon of velocity β = v/c and relativistic mass factor γ = (1 − β 2 ) − 1 2 is circulating in a horizontal plane due to a vertical magnetic field B, it will according to a Lorentz transformation experience both an electric and a magnetic field, E * and B * , in its own rest frame. The so-called motional electric field, E * = γc β × B, can be much larger than any practical applied electric field. Its action on the particle supplies the radial centripetal force, Thomas spin precession, and spin precession due to any non-vanishing EDM. B * produces precession due to the muon magnetic moment. The combined spi...
The cryogenic storage ring CSR Review of Scientific Instruments 87, 063115 (2016); https://doi
A "resonance method" of measuring the electric dipole moment (EDM) of nuclei in storage rings is described, based on two new ideas: (1) Oscillating particles' velocities in resonance with spin precession, and (2) alternately producing two sub-beams with different betatron tunes--one sub-beam to amplify and thus make it easier to correct ring imperfections that produce false signals imitating EDM signals, and the other to make the EDM measurement.
An rf Wien filter (WF) can be used in a storage ring to measure a particle's electric dipole moment (EDM). If the WF frequency equals the spin precession frequency without WF, and the oscillating WF fields are chosen so that the corresponding transverse Lorentz force equals zero, then a large source of systematic errors is canceled but the EDM signal is not. This effect, discovered by simulation, can be called the ''partially frozen spin'' effect.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.