Objective: To propose a new set of Japanese diagnostic reference levels (DRLs) and achievable doses (ADs) for 2017 and to verify the usefulness of Japanese DRLs (DRLs 2015) for CT, by investigating changes in the volume CT dose index (CTDIvol) from 2014 to 2017. Methods: Detailed information on the CT scan parameters used throughout Japan were obtained by questionnaire survey. The CTDIvol and dose-length product for the 11 commonest adult and 6 commonest paediatric CT examinations were surveyed and compared with 2014 data and DRLs 2015. Results: Evaluations of adult head (helical), and abdomen and pelvis without contrast agent, paediatric chest without contrast agent, and abdomen and pelvis without contrast agent showed a slightly lower mean CTDIvol in 2017 than in 2014 (t-test, p < 0.05). The interquartile range of CTDIvol for all 2017 examinations was lower than in 2014. Conclusions: This study verified the lower mean, 75th percentile, and interquartile range by investigating changes in the CTDIvol from 2014 to 2017. The DRLs 2015 contributed to CT radiation dose reduction. Advances in knowledge: The widespread implementation of iterative reconstruction algorithms and low-tube voltage in CT scanners is likely to facilitate further reduction in the CT radiation dose used in Japan. Although radiological technologists may require further education on appropriate CTDIvol and DLP usage, the DRLs 2015 greatly contributed to the reduction of the CT radiation dose used in Japan.
The purposes of this study were (1) to compare the radiation doses for 320- and 80-row fetal-computed tomography (CT), estimated using thermoluminescent dosimeters (TLDs) and the ImPACT Calculator (hereinafter referred to as the "CT dosimetry software"), for a woman in her late pregnancy and her fetus and (2) to estimate the overlapped fetal radiation dose from a 320-row CT examination using two different estimation methods of the CT dosimetry software. The direct TLD data in the present study were obtained from a previous study. The exposure parameters used for TLD measurements were entered into the CT dosimetry software, and the appropriate radiation dose for the pregnant woman and her fetus was estimated. When the whole organs (e.g., the colon, small intestine, and ovaries) and the fetus were included in the scan range, the difference in the estimated doses between the TLD measurement and the CT dosimetry software measurement was <1 mGy (<23 %) in both CT units. In addition, when the whole organs were within the scan range, the CT dosimetry software was used for evaluating the fetal radiation dose and organ-specific doses for the woman in the late pregnancy. The conventional method using the CT dosimetry software cannot take into account the overlap between volumetric sections. Therefore, the conventional method using a 320-row CT unit in a wide-volume mode might result in the underestimation of radiation doses for the fetus and the colon, small intestine, and ovaries.
Objective: The aims of this study are to propose a new set of Japanese diagnostic reference levels (DRLs) for 2014 and to study the impact of tube voltage and the type of reconstruction algorithm on patient doses. The volume CT dose index (CTDI vol ) for adult and paediatric patients is assessed and compared with the results of a 2011 national survey and data from other countries. Methods: Scanning procedures for the head (non-helical and helical), chest and upper abdomen were examined for adults and 5-year-old children. A questionnaire concerning the following items was sent to 3000 facilities: tube voltage, use of reconstruction algorithms and displayed CTDI vol . Results: The mean CTDI vol values for paediatric examinations using voltages ranging from 80 to 100 kV were significantly lower than those for paediatric examinations using 120 kV. For adult examinations, the use of iterative reconstruction algorithms significantly reduced the mean CTDI vol values compared with the use of filtered back projection. Paediatric chest and abdominal scans showed slightly higher mean CTDI vol values in 2014 than in 2011. The proposed DRLs for adult head and abdominal scans were higher than those reported in other countries. Conclusion:The results imply that further optimization of CT examination protocols is required for adult head and abdominal scans as well as paediatric chest and abdominal scans. Advances in knowledge: Low-tube-voltage CT may be useful for reducing radiation doses in paediatric patients. The mean CTDI vol values for paediatric scans showed little difference that could be attributed to the choice of reconstruction algorithm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.