PurposeNondegradable steel-and titanium-based implants are commonly used in orthopedic surgery. Although they provide maximal stability, they are also associated with interference on imaging modalities, may induce stress shielding, and additional explantation procedures may be necessary. Alternatively, degradable polymer implants are mechanically weaker and induce foreign body reactions. Degradable magnesium-based stents are currently being investigated in clinical trials for use in cardiovascular medicine. The magnesium alloy MgYREZr demonstrates good biocompatibility and osteoconductive properties. The aim of this prospective, randomized, clinical pilot trial was to determine if magnesium-based MgYREZr screws are equivalent to standard titanium screws for fixation during chevron osteotomy in patients with a mild hallux valgus.MethodsPatients (n=26) were randomly assigned to undergo osteosynthesis using either titanium or degradable magnesium-based implants of the same design. The 6 month follow-up period included clinical, laboratory, and radiographic assessments.ResultsNo significant differences were found in terms of the American Orthopaedic Foot and Ankle Society (AOFAS) score for hallux, visual analog scale for pain assessment, or range of motion (ROM) of the first metatarsophalangeal joint (MTPJ). No foreign body reactions, osteolysis, or systemic inflammatory reactions were detected. The groups were not significantly different in terms of radiographic or laboratory results.ConclusionThe radiographic and clinical results of this prospective controlled study demonstrate that degradable magnesium-based screws are equivalent to titanium screws for the treatment of mild hallux valgus deformities.
Limb rotation had a highly statistically significant effect on measured anatomic alignment and mechanical angles. A correlation between limb rotation, anatomic mechanical angle, mechanical angles measured at femur and tibia and the femoral component distance ratio was established. As the anatomic mechanical angle and the femoral component distance ratio change linearly in the range of 20 degrees internal and external limb rotation, a calculation of the femoral component distance ratio could be used to re-calculate the limb rotation at the time of radiographic assessment to evaluate the evidence of a long leg radiograph.
The Nanos short-stem hip implant shows only a slight initial migration within three months after implantation, followed by secondary stabilisation. These results suggest both good primary stability and osseo-integration, suggesting a low risk of aseptic loosening.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.