BackgroundThe stenosis of the coronary arteries is usually caused by atherosclerosis. Hemodynamic significance of patient-specific coronary stenoses and the risk of its progression may be assessed by comparing the hemodynamic effects induced by flow disorders. The present study shows how stenosis degree and variable flow conditions in coronary artery affect the oscillating shear index, residence time index, pressure drop coefficient and fractional flow reserve. We assume that changes in the hemodynamic indices in relation to variable flow conditions and geometries evaluated using the computational fluid dynamics may be an additional factor for a non-invasive assessment of the coronary stenosis detected on multi-slice computed tomography.MethodsThe local-parametrised models of basic shapes of the vessels, such as straight section, bend, and bifurcation as well as the global-patient-specific models of left coronary artery were used for numerical simulation of flow in virtually reconstructed stenotic vessels. Calculations were carried out for vessels both without stenosis, and vessels of 10 to 95% stenosis. The flow rate varied within the range of 20 to 1000 ml/min, and heart rate frequency within the range of 30 to 210 cycles/min.The computational fluid dynamics based on the finite elements method verified by the experimental measurements of the velocity profiles was used to analyse blood flow in the coronary arteries.ResultsThe results confirm our preliminary assumptions. There is significant variation in the coronary hemodynamic indices value caused by disturbed flow through stenosis in relation to variable flow conditions and geometry of vessels.ConclusionVariations of selected hemodynamic indexes induced by change of flow rate, heart rate and vessel geometry, obtained during a non-invasive study, may assist in evaluating the risk of stenosis progression and in carrying out the assessment of the hemodynamic significance of coronary stenosis. However, for a more accurate assessment of the variability of indices and coronary stenosis severity both local (near the narrowing) and global (in side branches) studies should be used.
Hemodynamic performance after Norwood with the RV-PA conduit is more effective than after Norwood with BTS. Computer simulations of complicated hemodynamics after the Norwood procedure could be helpful in establishing optimal post-Norwood physiology.
The aim of this work was the application of computer and physical in vitro simulation methods for estimating surgery procedure hemodynamics. The modified Blalock-Taussig (mB-T) palliative surgical procedure is performed to increase the pulmonary blood flow in children with congenital heart defects. Such a systemic-to-pulmonary shunt yields substantial modification in the blood flow within the large blood vessels. The objective of the present study was to investigate basic characteristics of the flow, flow pattern and pressure-flow efficiency, before and after opening of the mB-T graft. Methods The model was based on the vessel geometry obtained from the Visible Human Project and included the arch of aorta, the three arteries branching from the arch, the pulmonary trunck, and the left and right pulmonary arteries. The graft was added between the left subclavian artery and the left pulmonary artery. The glass model of the vessels was produced and investigated in a physical model of the cardiovascular system with an artificial ventricular device as the blood pump. Flow rate and hydrostatic pressure were measured at the inlet to and outlets from the glass model and in a few points within the system. Laser flow visualization was also performed. Computer simulations were done using the boundary conditions from the physical model. Results The opening of the mB-T graft changed flow distribution in all branches (including inflow). A complex flow pattern with large eddies and channelling of the flow in the vicinity of the graft and within it was observed in flow visualization and in computer simulations. Because of that complexity the local measurements of hydrostatic pressure at the vessel wall could not predict the average flow rate. The reversed flow in the graft was observed during the systole. Conclusions The complex flow pattern developed in the physical model of the mB-T graft. The channelling of the flow and the formation of large eddies may yield high shear stress and modify blood properties. The rigid wall model can describe only some flow characteristics observed in vivo. Computer simulation is a very fast and accurate method which permits earlier qualification of cardiac surgeons on how to change cardiac vascular blood flow after operations.
Objectives One of the most popular palliative procedures performed to increase pulmonary blood flow in children with congenital heart defects is a shunt operation (Blalock-Taussig graft or Glenn procedure), which creates the new blood channel to the pulmonary artery. The main problem with this kind of surgery is poor shunt effectiveness and the lack of possibility to regulate the flow. The aim of this work is to use advanced computer simulation methods to study the effectiveness of a new idea to introduce a small axial blood pump into a Blalock-Taussig (B-T) or Glenn shunt in order to control the blood flow and prevent any increase in the graft stenosis. Methods Physical and computer 3-D simulation based on a finite element mesh (FEM) model was applied. Studies for optimization of the shunt and hybrid shunt with pump were performed for different stages of the disease. Results and Conclusion The graft with the axial pump creates good conditions for the vascular system and pulmonary artery blood flow as well as regulating blood pressure under variable conditions caused by palliative procedures. Its use permits the afterload of the left heart ventricle to be decreased. A palliative procedure is only a temporary solution. When a child grows, while the graft size is fixed, the blood flow through this graft may be not sufficient under changing hemodynamic conditions. The use of an axial pump for regulating the blood flow volume, during palliative procedures, allows to obtain the optimal flow conditions in pulmonary artery and safely wait on the final cardiac surgery correction later. However, the use of a pump mounted inside the graft increased hemodynamic resistance, which caused the flow to decrease up to 70% in the graft when the axial pump was not working.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.