of coronavirus disease (COVID-19) had been reported globally since December 2019 (1), severely burdening the healthcare system (2). The extremely fast transmission capability of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has aroused concern about its various transmission routes.The main transmission routes for SARS-CoV-2 are respiratory droplets and close contact (3). Knowing the extent of environmental contamination of SARS-CoV-2 in COVID-19 wards is critical for improving safety practices for medical staff and answering questions about SARS-CoV-2 transmission among the public. However, whether SARS-CoV-2 can be transmitted by aerosols remains controversial, and the exposure risk for close contacts has not been systematically evaluated. Researchers have detected SARS-CoV-2 on surfaces of objects in a symptomatic patient's room and toilet area (4). However, that study was performed in a small sample from regions with few confirmed cases, which might not reflect real conditions in outbreak regions where hospitals are operating at full capacity. In this study, we tested surface and air samples from an intensive care unit (ICU) and a general COVID-19 ward (GW) at Huoshenshan Hospital in Wuhan, China (Figure 1). The StudyFrom February 19 through March 2, 2020, we collected swab samples from potentially contaminated objects in the ICU and GW as described previously (5). The ICU housed 15 patients with severe disease and the GW housed 24 patients with milder disease. We also sampled indoor air and the air outlets to detect aerosol exposure. Air samples were collected by using a SASS 2300 Wetted Wall Cyclone Sampler (Research International, Inc., https://www.resrchintl.com) at 300 L/min for of 30 min. We used sterile premoistened swabs to sample the floors, computer mice, trash cans, sickbed handrails, patient masks, personal protective equipment, and air outlets. We tested air and surface samples for the open reading frame (ORF) 1ab and nucleoprotein (N) genes of SARS-CoV-2 by quantitative real-time PCR. (Appendix, https://wwwnc.cdc.gov/EID/ article/26/7/20-0885-App1.pdf).Almost all positive results were concentrated in the contaminated areas (ICU 54/57, 94.7%; GW 9/9, 100%); the rate of positivity was much higher for the ICU (54/124, 43.5%) than for the GW (9/114, 7.9%) (Tables 1, 2). The rate of positivity was
Severe cases of coronavirus disease 2019 (COVID-19) cannot be adequately managed with mechanical ventilation alone. The role and outcome of extracorporeal membrane oxygenation (ECMO) in the management of COVID-19 is currently unclear. Eight COVID-19 patients have received ECMO support in Shanghai with seven with venovenous (VV) ECMO support and one veno arterial (VA) ECMO during cardiopulmonary resuscitation. As of March 25, 2020, four patients died (50% mortality), three patients (37.5%) were successfully weaned off ECMO after 22, 40, and 47 days support, respectively, but remain on mechanical ventilation. One patient is still on VV ECMO with mechanical ventilation. The partial pressure of oxygen/fractional of inspired oxygen ratio before ECMO initiation was between 54 and 76, and all were well below 100. The duration of mechanical ventilation before ECMO ranged from 4 to 21 days. Except the one emergent VA ECMO during cardiopulmonary resuscitation, other patients were on ECMO support for between 18 and 47 days. In conclusion, ensuring effective, timely, and safe ECMO support in COVID-19 is key to improving clinical outcomes. Extracorporeal membrane oxygenation support might be an integral part of the critical care provided for COVID-19 patients in centers with advanced ECMO expertise.
Objective: To explore special coagulation characteristics and anticoagulation management in extracorporeal membrane oxygenation (ECMO)À assisted patients with coronavirus disease 2019 (COVID-19). Design: Single-center, retrospective observation of a series of patients. Participants: Laboratory-confirmed severe COVID-19 patients who received venovenous ECMO support from January 20ÀMay 20, 2020. Interventions: This study analyzed the anticoagulation management and monitoring strategies, bleeding complications, and thrombotic events during ECMO support. Measurements and Main Results: Eight of 667 confirmed COVID-19 patients received venovenous ECMO and had an elevated D-dimer level before and during ECMO support. An ECMO circuit pack (oxygenator and tubing) was replaced a total of 13 times in all 8 patients, and coagulation-related complications included oxygenator thrombosis (7/8), tracheal hemorrhage (5/8), oronasal hemorrhage (3/8), thoracic hemorrhage (3/ 8), bleeding at puncture sites (4/8), and cannulation site hemorrhage (2/8). Conclusions: Hypercoagulability and secondary hyperfibrinolysis during ECMO support in COVID-19 patients are common and possibly increase the propensity for thrombotic events and failure of the oxygenator. Currently, there is not enough evidence to support a more aggressive anticoagulation strategy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.