An integrated airfoil alkali metal high temperature heat pipe structure is proposed for the air rudder. The heat transfer properties of lithium and sodium are analyzed, and the equal thickness test pieces are designed and prepared. The sonic limit, condensation limit, viscosity limit, entrainment limit, capillary limit and boiling limit are calculated theoretically, and the corresponding feasible working areas are drawn according to each limit curve. It is found that the optimal working temperature range of the test piece is 800 K ~ 1500 K. The effects of heating power and placement angle on the start-up time, isothermal performance and heat transfer performance of the test piece are studied by experiments. It is found that the increase of heating power is helpful to shorten the start-up time and improve the isothermal performance and heat transfer performance of the test piece. The placement angle has little effect on the start-up time, but it has effect on the isothermal performance and heat transfer performance.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.