We have developed a new system for the production of autologous platelet-rich plasma and red blood cell concentrates to be used in autologous transfusion support of cardiac surgery patients. In 15 operations no homologous blood products were required. Costs were diminished since with the same harness it was possible to carry out the intraoperative blood salvage and concentrate the erythrocytes contained in the oxygenator and its lines. Indirect costs were also reduced since no infective complication was observed due to homologous blood products.
A variety of health problems occur consistently following C. jejuni enteritis and substantially increase morbidity due to campylobacteriosis in the community.
Refractory ascites is an infrequent complication of cirrhosis. Paracentesis and ultrafiltration of the ascitic fluid with intravenous or intraperitoneal reinfusion of the concentrated ascites has been used as therapy for this condition since 1971. The technique is cumbersome and has high morbidity and mortality rates, even if effective. In this paper we describe a new technique that couples secondary filtration for the removal of macromolecules, with ultrafiltration of ascitic fluid. In its very first application 6 patients underwent 8 treatments. No adverse effect was observed and clinical efficacy was good. Up to 60 g of albumin can be saved in a single session lasting less than 2 hours.
Among the many blood cell separators introduced into the international market in these last few years, the Fresenius AS 104 represents an advanced and safe thrombocytapheresis machine whose development took advantage of extensive worldwide experience with blood cell separation. Nonetheless the AS 104 has generated most interest in West Germany and most, if not all, the studies published on its platelet collection efficiency have been carried out in that country. It is normally reported that from 2.7 to 3.5 x 10(11) platelets can be collected in approximately 80 minutes. Since these results could not be duplicated routinely in our hemapheresis unit, we set up a study by modifying the standard procedure. It was possible to reduce the procedure time and to collect platelet concentrates containing more than 4 x 10(11) cells on a routine basis by using the following procedure: ACD-A/blood ratio 1:10; Interface position 6:2; blood flow rate always exceeding 65 mL/min; rpm 1750; cell collection from 4 to 7 mL/min; volume of blood processed 3.6 L followed by the rinsing of the system with 200 ml of saline; extraction of the content of the secondary separation chamber by the action of the plasma pump working at 20 mL/min for 2 min. With this procedure the platelet yield in 34 collections exceeded 3.1 x 10(11) and averaged 4.06 x 10(11). The procedure time was reduced to 56.5 minutes with a mean blood flow rate of 62.3 mL/min. The leukocyte and erythrocyte contamination of the products were in the range of 1 x 10(7) and 1 x 10(8) respectively.(ABSTRACT TRUNCATED AT 250 WORDS)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.