Objective
We performed a systematic review and meta‐analysis of randomized clinical trials on adult patients undergoing cardiac surgery and compared the rates of red blood cell (RBC), platelet and fresh frozen plasma (FFP) transfusion between the cell saver (CS) and the standard of care groups.
Methods
MEDLINE ®, The Cochrane Central Register of Controlled Trials (CENTRAL), American Society of Hematology (ASH) and bibliographies of relevant studies were searched. We used random‐effect model.
Results
Our search strategy returned 624 citations, of which 15 studies were selected. The use of CS did not decrease the rate of RBC transfusion (odds ratio [OR]: 0·69; 95% CI: 0·48–1·00), albeit with a substantial heterogeneity (I2 = 60%). The year of publication explained most of the heterogeneity (P for subgroup effect <0·001). Although the rate of platelet transfusion was lower in the CS group, the difference was not statistically significant (OR: 0·83; 95% CI: 0·57–1·2; I2 = 0%). The rate of FFP transfusion was numerically higher in the CS group; however, this difference did not reach statistical significance (OR: 1·26; 95% CI: 0·82–1·94; I2 = 15%). Only two studies scored five on the Jadad score. There was no indication of a publication bias using the funnel plot and Egger test (P = 0·34, 0·87, and 0·62 for RBC, platelet and FFP, respectively).
Conclusion
The use of CS during cardiac surgery does not have an impact on the rates of RBC, platelet and FFP transfusion; however, this should be interpreted in the light of the study limitations.
The incidence of autism spectrum disorders (ASD) has been rising, but the causes of ASD remain largely unidentified. Collective data have implicated the increased human exposure to electromagnetic fields (EMF) in the increasing incidence of ASD. There are established biological effects of extremely low-frequency (ELF) EMF, but the relation to ASD is not investigated enough. In this study we examined the effects of perinatal exposure to ELF EMF on some ASD-relevant behavioral parameters in mice. The EMF was delivered via a Helmholtz coil pair. Male BALB/C mice were used and divided into exposed and control groups (n=8 and n=9, respectively). Tests were used to assess sociability, preference for social novelty, locomotion, anxiety, exploratory behavior, motor coordination, and olfaction. The examined mice were all males and exposed to EMF during the last week of gestation and for 7 days after delivery. The exposed mice demonstrated a lack of normal sociability and preference for social novelty while maintaining normal anxiety-like behavior, locomotion, motor coordination, and olfaction. Exposed mice also demonstrated decreased exploratory activity. We concluded that these results are supportive of the hypothesis of a causal link between exposure to ELF-EMF and ASD; however, replications of the study with further tests are recommended.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.