We demonstrate in this study the potential of near infrared (NIR) spectroscopy as a tool for monitoring progression of cartilage degeneration in an animal model. Osteoarthritic degeneration was artificially induced in one joint in laboratory rats, and the animals were sacrificed at four time points: 1, 2, 4, and 6 weeks (3 animals/week). NIR spectra were acquired from both (injured and intact) knees. Subsequently, the joint samples were subjected to histological evaluation and glycosaminoglycan (GAG) content analysis, to assess disease severity based on the Mankin scoring system and to determine proteoglycan loss, respectively. Multivariate spectral techniques were then employed for classification (principal component analysis and support vector machines) and prediction (partial least squares regression) of the samples’ Mankin scores and GAG content from their NIR spectra. Our results demonstrate that NIR spectroscopy is sensitive to degenerative changes in articular cartilage, and is capable of distinguishing between mild (weeks 1&2; Mankin <=2) and advanced (weeks 4&6; Mankin =>3) cartilage degeneration. In addition, the spectral data contains information that enables estimation of the tissue’s Mankin score (error = 12.6%, R2 = 86.2%) and GAG content (error = 7.6%, R2 = 95%). We conclude that NIR spectroscopy is a viable tool for assessing cartilage degeneration post-injury, such as, post-traumatic osteoarthritis.
Equal channel angular extrusion (ECAE) is a severe plastic deformation (SPD) method for obtaining bulk nanostructured materials. The ECAE die consists of two equal channels that intersect at an angle, usually between 90。and 135。. In the present study, the plastic deformation behavior of copper during the ECAE process with 120o die was investigated. To analyze the deformation behavior and the related strain distributions in the specimen, the commercial FE code ABAQUS has been used. The properties of the materials are strongly dependent on the shear plastic deformation behavior during equal channel angular extrusion (ECAE), which is controlled mainly by die geometry, material properties, and the friction between billet and the die. The ECAE process for these conditions was explained using the two different friction conditions of 0.15 and 0.08 to all sliding surfaces. The effective strain by the theoretical equation is in good agreement with the FEM results.
The purpose of this study was to investigate the influence of Temporomandibular Joint implant geometry on stress distribution in total reconstruction of temporomandibular joint. A three dimensional model of a lower jaw of a patient was developed from a Computed Tomography scan images. Anatomical curvature and flat contact surface of implant design and fixation screws were modeled. Two implanted mandibles were then compared by means of finite element analysis. The muscle forces for incisal clenching were applied. The equivalent stress resulted in contact surface region of the bone and implant and in fixation screw holes were investigated to evaluate the designs. In applied loading condition, The results showed that anatomical design of implant was more preferred and it will lead to long-term success of implant.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.