Cholinesterase sensors based on screen-printed electrodes modified with polyaniline, 7,7',8,8'-tetracyanoquinodimethane (TCNQ), and Prussian blue have been developed and tested for detection of anticholinesterase pesticides in aqueous solution and in spiked grape juice. The influence of enzyme source and detection mode on biosensor performance was explored. It was shown that modification of the electrodes results in significant improvement of their analytical characteristics for pesticide determination. Thus, the slopes of the calibration curves obtained with modified electrodes were increased twofold and the detection limits of the pesticides were reduced by factors of 1.6 to 1.8 in comparison with the use of unmodified transducers. The biosensors developed make it possible to detect down to 2 x 10(-8) mol L(-1) chloropyrifos-methyl, 5 x 10(-8) mol L(-1) coumaphos, and 8 x 10(-9) mol L(-1) carbofuran in aqueous solution and grape juice. The optimal conditions for grape juice pretreatment were determined to diminish interference from the sample matrix.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.