Design studies method of star sensor thermal stability with liquid cooling using modern CAD has been described. Optimal operation of two circuits for liquid cooling structure of star sensor has been chosen using a mathematical model for calculating the convective heat transfer coefficient. Study defined the angular displacement of the star sensor with liquid cooling (~ 0.3 arc seconds), which is acceptable for star sensors with 1 arc seconds accuracy. At this level of scientific investigation the developed 3D model of the star sensor assembly comprising a thermally stabilizing ground test equipment allows to determine the angular error due to the temperature loads and optimal parameters liquid of cooling system (for example, the flow rate of fluid , geometrical parameters of cooling circuits , etc.). In the future, this model should be improved, which will consider the impact of other factors (e.g. gravity, vibration, etc.) on the performance of the star sensor.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.