Introduction: Metabolic Tumor Volume (MTV) and Total Tumor Lesion Glycolysis (TLG) are used in 18F-fluorodeoxyglucose Positron-Emission Tomography combined with Computed Tomography (18F-FDG PET/CT) as functional markers, indicating tracer uptake in whole tumor. MTV and TLG are not yet engaged in clinical practice, because volume measurement accuracy depends on the selected measurement method, and optimal MTV and TLG segmentation is not established.Purpose: Assessment of accuracy of metabolic tumor volume measurement ways, using 18F-FDG PET/CT in patients with Diffuse Large B-Cell Lymphoma (DLBCL).Material and methods: Baseline 18F-FDG PET/CT performed in 21 patients with DLBCL. Tumor Volume (TV), measured on contrast enhanced CT (CTTV), considered as reference. While measuring MTV, we aimed to achieve a 1:1 ratio between CTTV and MTV. If anatomical and metabolic tumor contours matched, MTV was considered true (MTVtrue). Overall MTV and TLG measurements are 254. Tumor contouring, using relative thresholds, was made around Standardized Uptake Value (SUVmax) of tracer in tumor and intact liver.Results: On CT, the size of the lesions varied from 24 to 241 mm, M = 103.4±62.3, Me = 93 (48.5–155.5). In 15 (71.4 %) foci, hypodense areas of necrosis were determined. PET imaging revealed high tracer uptake in all foci of varying degrees of intensity. SUVmax values in tumors ranged from 5.8 to 30.5, Me = 20.4 (17.3–23.2). No significant correlation was found between the size of the foci and SUVmax (ρ = 0.17, p = 0.4744). The best accuracy in measuring MTV was observed when several thresholds were applied: VOIPERCIST, VOI2.5, VOIauto-contour, as well as VOI10 %, VOI15 % and VOI20 %. The optimal absolute threshold values were SUV values in the range from 2 to 3, and relative values in the range from 10 % to 20 % of the SUVmax in the tumor. MTV underestimation was more often determined using relative cut-off indices in the range of25–50 % and SUV thresholds ≥ 5.3.Conclusion: The results obtained showed that the use of a single threshold value for MTV segmentation in patients with DLBCL is not advisable. The choice of the MTV measurement method should be carried out individually for each lesion, taking into account its shape, size and structure, as well as the intensity and uniformity of tracer uptake in the tumor and adjacent anatomical structures.
No abstract
We present two clinical cases of conjunctival lymphoma, the disease which is classified as a malignant tumor of the eye. Conjunctival lymphoma has systemic involvement. Patients presented in our monitoring study received a conservative treatment for chronic conjunctivitis over a long period of time. The article considers the diagnostics and treatment plan of lymphoproliferative eye disease, which allows an increased effectiveness of treating.
The technique described by Jannetta uses Teflon "turfs" (polytetrafluoroethylene). With the technological advancement of materials it is increasingly harder to nd Te on in the market. The author describes a technique which uses a portion of a vascular prosthesis made of polyester (FlowNit Bioseal ®) manufactured by JOTEC ® Gmbh reference 35BI1206. The use of this vascular prosthesis seems to be an effective alternative for intracranial neurovascular decompression. One of its advantages is having a circumferential format, which provides greater stability and safety to possible displacement.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.