Phosphoglycerate kinase catalyses the high-energy phosphoryl transfer of the acyl phosphate of 1,3-bisphosphoglycerate to ADP to produce ATP, a reaction requiring magnesium ions. The enzyme is widely distributed and apparently highly conserved as a monomer of molecular mass 45 000. X-ray studies of the enzymes from horse muscle and yeast, carried out in Oxford and Bristol respectively, have shown that the molecular structures of the two enzymes are almost identical. The most striking aspect of the structure is that the single polypeptide chain is organized into two separated domains composed of the N-terminal and C-terminal halves of the chain. Substrate binding studies and the determination of the complete amino acid sequence of the horse enzyme suggest that the nucleotide substrates and the phosphoglycerate substrates are bound to the C-domain and N-domain, respectively, in sites that are separated by about 12 A. In order to bring the two substrates together for catalysis, a hinge-bending conformational change involving helix rotation has been proposed, for which there is independent evidence from solution studies. Crystals of the ternary complex of the horse enzyme have been prepared that may contain the folded form of the enzyme.
In mobile healthcare device, when to measure the heart rate by using the PPG signal, its performance is reduced according to the motion artifacts that is the movement of user. This is because the frequency range of motion (0.01-10 Hz) and that of PPG signals overlap. Also, the motion artifacts cannot be rectified by general filters. To solve the problem, this paper proposes a method using filter banks and independent component analysis (ICA). To evaluate the performance of the proposed method, we were artificially applied various movements and compared heart rate errors of the moving average filter and ICA. In the experimental results, heart rate error of the proposed method showed very low than moving average filter and ICA. In this way, it is possible to measure stable heart rate if the proposed method is applied to the healthcare terminal design.키워드 : 광용적 맥파, 심박수, 독립성분분석법, 필터뱅크, 동잡음
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.