1997
DOI: 10.1023/a:1018304117895
|View full text |Cite
|
Sign up to set email alerts
|

Untitled

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
132
0

Year Published

2003
2003
2011
2011

Publication Types

Select...
5
4

Relationship

2
7

Authors

Journals

citations
Cited by 213 publications
(135 citation statements)
references
References 13 publications
3
132
0
Order By: Relevance
“…These values may correspond to micelle-associated ForC GBD. It should be noted here that the D values for the fully unfolded protein may be in the same range (44). However, based on the CD measurements, the DPC micelle-immersed form is not unfolded but has a high content of secondary structure.…”
Section: Resultsmentioning
confidence: 84%
“…These values may correspond to micelle-associated ForC GBD. It should be noted here that the D values for the fully unfolded protein may be in the same range (44). However, based on the CD measurements, the DPC micelle-immersed form is not unfolded but has a high content of secondary structure.…”
Section: Resultsmentioning
confidence: 84%
“…The molecular dimensions of N and MFI species were compared by performing NMR pulsed-field gradient diffusion measurements (12,13,18,19). The approach focused on the estimation of the effective hydrodynamic radii of both species with a pulsed-gradient-stimulated echo longitudinal encode-decode pulse sequence (12,18) in which the protein NMR signal decay is measured as a function of gradient field strength. The signal decay rate is proportional to the diffusion coefficient D, which is itself inversely proportional to the effective hydrodynamic radius, R H .…”
Section: Resultsmentioning
confidence: 99%
“…All NMR data were processed by using FELIX 2.3 software from Biosym Technologies (San Diego). Pulsed-field gradient diffusion measurements were performed with a pulsed gradient stimulated echo longitudinal encode-decode pulse sequence (12,13). The length of pulses and delays was held constant, and 20 spectra were acquired with the strength of the diffusion gradient varying between 5% and 100% of its maximum value; each measurement was repeated six times to improve the signal-to-noise ratio and to allow the measurement error to be estimated.…”
Section: Rp-hplc and Electrospray Ionization-ms (Esi-ms)mentioning
confidence: 99%
“…These experiments were also recorded with the reconstituted Ig2/70S sample for comparison. 1 H PFG-LED diffusion measurements (34) were also recorded for RNC samples, to monitor the translational diffusion of the 70S ribosome by using the observable proton resonances of the stalk L7/L12 proteins (20). HNCO experiments ( 1 H-15 N or 1 H-13 C correlation projections) were recorded and revealed that the observed 1 H- 15 N correlations in the SOFAST-HMQC spectra could not arise from free amino acids because the presence of a peptide bond is the prerequisite for detection of H i N i CO iϪ1 correlations (35).…”
Section: Methodsmentioning
confidence: 99%