2020
DOI: 10.1109/tps.2019.2955497
|View full text |Cite
|
Sign up to set email alerts
|

2-D Evaluation of Bred Tritium Using Neutron Imaging Plate

Abstract: Tritium breeding performance of a fusion blanket is a key parameter for the self-sufficient fueling of a fusion reactor and thus planned to validate the performance in a neutronics experiment. Measuring the two-dimensional (2D) distribution of bred tritium is challenging via conventional methods such as -ray counting from an irradiated lithium sample by a liquid scintillation counter and a single-crystal diamond detector with a thin 6 LiF film because they are point detectors which require many measurements. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 18 publications
0
6
0
Order By: Relevance
“…3 IEC has been studied intensively during the last three decades, and its current, compact design provides a smallscale neutron source for diverse applications worldwide. [4][5][6][7][8][9][10][11][12][13] The ideal configuration of an IEC device is a spherical grid cathode surrounded by a spherical anode. A potential difference of tens of kV is applied between the electrodes to establish a potential well for trapping ions and beginning discharge.…”
Section: Introductionmentioning
confidence: 99%
“…3 IEC has been studied intensively during the last three decades, and its current, compact design provides a smallscale neutron source for diverse applications worldwide. [4][5][6][7][8][9][10][11][12][13] The ideal configuration of an IEC device is a spherical grid cathode surrounded by a spherical anode. A potential difference of tens of kV is applied between the electrodes to establish a potential well for trapping ions and beginning discharge.…”
Section: Introductionmentioning
confidence: 99%
“…Both the cathode and anodes were coated with Ti to increase the neutron yield [24]. The neutron yield was monitored by GE Reuter Stokes 3 He gas-filled detector, which was shielded by Pb foil (2 mm thickness) to minimize miscounts by bremsstrahlung x-rays during discharge in a high voltage condition [12]. The counter was calibrated with a spontaneous fission neutron source of 252 Cf (1.08 × 10 4 Bq with a neutron production rate of 1.25 × 10 3 n s −1 ) placed at the center of the cathode in the device for monitoring the number of source neutron (s.n.…”
Section: Neutron Sourcementioning
confidence: 99%
“…The downward sloping peaks below 0.75 MeV were detected whether with the 6 LiF film or without (figures 7(a) and (b)). These peaks were mainly caused by the energy deposition by 12 C, originating from 12 C(n, n ) 12 C elastic scattering of fast neutrons in the diamond. The intensity of 12 C peak per unit irradiation time at position A was the highest among the five positions, which was consistent with the highest fast neutron flux at position A (figure 5).…”
Section: Evaluation Of Tprmentioning
confidence: 99%
See 2 more Smart Citations