2017 IEEE International Solid-State Circuits Conference (ISSCC) 2017
DOI: 10.1109/isscc.2017.7870407
|View full text |Cite
|
Sign up to set email alerts
|

21.2 A 1.4mΩ-sensitivity 94dB-dynamic-range electrical impedance tomography SoC and 48-channel Hub SoC for 3D lung ventilation monitoring system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 3 publications
0
4
0
Order By: Relevance
“…where '0)12 is the noise of the analog front-end and 12'12 is the measurement sensitivity in Ω/√ [22], [23]. The 12'12 value can reflect the front-end performance but does not reflect the overall EIT system performance.…”
Section: Current Eit System Evaluation Metricsmentioning
confidence: 99%
“…where '0)12 is the noise of the analog front-end and 12'12 is the measurement sensitivity in Ω/√ [22], [23]. The 12'12 value can reflect the front-end performance but does not reflect the overall EIT system performance.…”
Section: Current Eit System Evaluation Metricsmentioning
confidence: 99%
“…Electrochemical impedance spectroscopy (EIS) is used in various sensor applications that require impedance measurement of a specific target [1][2][3][4][5][6][7]. Notable examples include gas concentration measurement [1], battery condition measurement, [2] human body composition analysis [3], impedance cardiography [4], and lung ventilation monitor [5]. It is also applied to systems that detect molecular substances ranging from intracellular action potential [6], DNA [7], and RNA [8] detection.…”
Section: Introductionmentioning
confidence: 99%
“…However, these traditional EIT systems were constructed with commercial off-the-shell (COTS) discrete components introducing noise through the wires during the signal transmission from electrodes to processing system. With the maturity of integrated circuit technology, system-on-chip (SoC) has contributed to portable EIT systems [5][6] which are smaller in size, low cost, low power and feasible for home use. The present EIT systems have much room for improvement for the sensing accuracy.…”
Section: Introductionmentioning
confidence: 99%
“…In addition, it is difficult to realize a high sensitivity system with a limited resolution ADC. Though the resolution of ADC is limited, M. Kim, et al, propose to average the measurements in different cycles to improve the sensitivity [6]. In this paper, a digital lock-in amplifier is proposed to increase the accuracy and sensitivity of the EIT system.…”
Section: Introductionmentioning
confidence: 99%