TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference 2007
DOI: 10.1109/sensor.2007.4300379
|View full text |Cite
|
Sign up to set email alerts
|

32 � 32 pH Image Sensors for Real Time Observation of Biochemical Phenomena

Abstract: 32 × 32 pH image sensors were successfully fabricated by using the CCD/CMOS image sensor technique, and real time imaging of a chemical reaction and pH distribution was carried out for the first time. The pH variations by a chemical reaction are observed by 200 ms step (i.e. 5 flames per sec). The pH image sensor was able to take a pH image of mouse stomach successfully. It means that the novel image sensor can be applied to a biomedical and biochemical field.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
15
0

Year Published

2010
2010
2019
2019

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 22 publications
(15 citation statements)
references
References 4 publications
0
15
0
Order By: Relevance
“…The CCD ion image sensor has been described elsewhere [18,19]. The measurement principles and its operation are briefly described.…”
Section: Ccd Ion Image Sensormentioning
confidence: 99%
See 1 more Smart Citation
“…The CCD ion image sensor has been described elsewhere [18,19]. The measurement principles and its operation are briefly described.…”
Section: Ccd Ion Image Sensormentioning
confidence: 99%
“…A CCD pH image sensor equipped with 100 pixels (10 10) has been reported [17]. Moreover, a CCD pH image sensor containing 1024 pixels (32 32) successfully obtained a biological image in 0.2 s steps [18]. Using the CCD pH image sensor that surpassed other electrochemical ion image sensors in speed, we developed a CCD potassium ion image sensor that was combined with a plasticized PVC membrane [19].…”
Section: Introductionmentioning
confidence: 99%
“…The POSS 1,3,5,7,9,11,13,15-octa(propylmethacryl)pentacyclo-[9.5.1.1 3,9 .1 5,15 .1 7,13 ]octasiloxane (OPMPCOS), high molecular weight PVC (average MW = 500000), and tris(hydroxymethyl)aminomethane (Tris) were purchased from Sigma-Aldrich. Dioctyl phthalate (DOP) and other reagents were prepared from analytical reagent grade chemicals (Wako Pure Chemicals, Japan).…”
Section: Reagents and Solutionsmentioning
confidence: 99%
“…The potential response was linear from 10 -2 to 10 -5 M logarithmic concentration of potassium ion. The selectivity coefficients were K (10 × 10) 6 and 1024 pixels (32 × 32) 7 have been developed for pH sensing. Images of the pH of a biological sample were successfully obtained using a 200-ms step, while the recording time of a LAPS microscope was not as rapid.…”
Section: Introductionmentioning
confidence: 99%
“…pH by measuring the amount of charge that is present [8]- [10]. The charge accumulation operation realized pH sensitivity of more than 1 V/pH, with an accuracy of better than 0.002 pH [11], [12].…”
mentioning