A Critical Analysis of the Thermoacoustic Microscope

Abstract: S t a t e U n i v e r s i t y , U e t r o i t , M I 482U2 Abstract A one-dimensional a n a l y s i s o f t h e inechani sms by which a c o u s t i c waves a r e generated i n t h e thermoacoustic microscope i s presented. Thermal waves and a c o u s t i c waves a r e t r e a t e d as eigen-modes o f t h e system, so t h a t t h e r e i s no a c o u s t i c wave generated by thermal waves i n t h e bulk. It i s then shown t h a t t h e r e a r e f o u r channels by which t h e i n c i d e n t energy can be conv… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
3
0

Year Published

1985
1985
1987
1987

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 5 publications
1
3
0
Order By: Relevance
“…According to theoretical estimates based solely on thermal wavelength, it should not be possible to record changes in surface thermal properties on a depth scale less than about 10 microns for this frequency, while the implant depth is only about 0.1 microns. However, consideration of the volume into which the energy is deposited and from which the thermal and acoustic waves propagate into the solid is the other part of resolution in thermal microscopies so that our observations are in good agreement with current theory [22].…”
Section: Iam Imagessupporting
confidence: 84%
“…According to theoretical estimates based solely on thermal wavelength, it should not be possible to record changes in surface thermal properties on a depth scale less than about 10 microns for this frequency, while the implant depth is only about 0.1 microns. However, consideration of the volume into which the energy is deposited and from which the thermal and acoustic waves propagate into the solid is the other part of resolution in thermal microscopies so that our observations are in good agreement with current theory [22].…”
Section: Iam Imagessupporting
confidence: 84%
“…These equations and their solut·ions have been described elsewhere [10,11]. These solutions were obtained by separating the coupled equations into equations for their uncoupled normal modes.…”
Section: Theorymentioning
confidence: 99%
“…we have evaluated the effects of the presence of a free surface and have calculated [10] the relative efficiencies of tour distinct processes for imaging of a discontinuity such as a grain boundary. It is assumed that the source is an electron or photon beam for which the momentum contribution to the waves is small compared to the energy contribution.…”
Section: Theorymentioning
confidence: 99%
“…This work strongly supports the Jackson -Amer thermal bending model [3] for low frequency (up to approximately 100kHz in small specimens) acoustic detection in the solid as compared to the theory of Opsal and Rosencwaig [4] which does not incorporate total specimen response to the thermal source. This problem has more recently been theoretically investigated by Favro [5,6], who has developed a more general theory encompasing both the Opsal-Rosencwaig short wavelength limit and the Jackson-Amer long wavelength limit. Favro's theory also accounts for features in the image shown.…”
Section: Introductionmentioning
confidence: 99%