2012
DOI: 10.1109/tim.2012.2192345
|View full text |Cite
|
Sign up to set email alerts
|

A Flow Measurement Technique Using a Noncontact Capacitance-Type Orifice Transducer for a Conducting Liquid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
19
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
7
2

Relationship

2
7

Authors

Journals

citations
Cited by 37 publications
(19 citation statements)
references
References 15 publications
0
19
0
Order By: Relevance
“…The direct method is to measure the flow rate through a pipeline by using conventional flow rate meters. 7 The indirect method is to estimate the flow rate by employing speed/position transducers or some other particular techniques. 8,9 The intervention of speed/position transducers and peripheral hardware to acquire the flow rate information would be necessitated when the latter method is adopted.…”
Section: Introductionmentioning
confidence: 99%
“…The direct method is to measure the flow rate through a pipeline by using conventional flow rate meters. 7 The indirect method is to estimate the flow rate by employing speed/position transducers or some other particular techniques. 8,9 The intervention of speed/position transducers and peripheral hardware to acquire the flow rate information would be necessitated when the latter method is adopted.…”
Section: Introductionmentioning
confidence: 99%
“…The effect of the offset voltage V OS of the opamp OA can be seen in v oi during T 1 , as C I will acquire an extra charge of ∓N 1 T C V OS /R I due to V OS in addition to 1 T Q given by (2).…”
Section: F Other Sources Of Error In the Main Cdcmentioning
confidence: 99%
“…APACITIVE sensors are widely accepted in the industry for many applications such as flow measurement [1], [2], level measurement [3], proximity detection [4], [5], measurement of humidity [6], [7], detection of ice layer [8], angular position sensing [9], etc. An interdigitated capacitive sensor has been developed for detecting some of the chemicals related to food poisoning and presented in [10].…”
Section: Introductionmentioning
confidence: 99%
“…Various works on the development and application of new and modified techniques of flow measurement are still being reported. Bera and Mandal [7] have designed a noncontact capacitance-type orifice for the measurement of flow rate of a conducting liquid through a pipeline. Beaulieu et al [8] have developed a flow meter for measurement of unsteady liquid flow using venturi tube and modified version of the unsteady Bernoulli equation.…”
Section: Introductionmentioning
confidence: 99%