2006
DOI: 10.1007/s10439-006-9122-8
|View full text |Cite
|
Sign up to set email alerts
|

A Markerless Motion Capture System to Study Musculoskeletal Biomechanics: Visual Hull and Simulated Annealing Approach

Abstract: Human motion capture is frequently used to study musculoskeletal biomechanics and clinical problems, as well as to provide realistic animation for the entertainment industry. The most popular technique for human motion capture uses markers placed on the skin, despite some important drawbacks including the impediment to the motion by the presence of skin markers and relative movement between the skin where the markers are placed and the underlying bone. The latter makes it difficult to estimate the motion of th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
134
1
3

Year Published

2009
2009
2016
2016

Publication Types

Select...
5
2
2

Relationship

0
9

Authors

Journals

citations
Cited by 279 publications
(151 citation statements)
references
References 33 publications
2
134
1
3
Order By: Relevance
“…Table 1 shows the comparative results in terms of mean (m e ) and standard deviation (σ e ) of joint's angles compared to the ground truth over the gait cycle. The results, with a mean value of 2.63±2.61, are particularly encouraging and present same magnitude to the ones obtained with 3D markerless systems or 2D complex model based ones [9] [12]. The image resolution and the silhouette's height reduce the algorithm performance, as predictable.…”
Section: Experimental Testssupporting
confidence: 71%
See 1 more Smart Citation
“…Table 1 shows the comparative results in terms of mean (m e ) and standard deviation (σ e ) of joint's angles compared to the ground truth over the gait cycle. The results, with a mean value of 2.63±2.61, are particularly encouraging and present same magnitude to the ones obtained with 3D markerless systems or 2D complex model based ones [9] [12]. The image resolution and the silhouette's height reduce the algorithm performance, as predictable.…”
Section: Experimental Testssupporting
confidence: 71%
“…Since the video processing approach does not rely on the use of markers, this research area has been addressed as "markerless" [8]. Some approaches found in literature are based on the visual hull reconstruction and an a priori 3D human model by using a large number of video cameras [9][10]. However, in clinical gait analysis, since the majority of gait pathological knee, ankle and foot dysfunctions occur in the sagittal plane [11], markerless lower limbs' motion estimation literature is generally 2D oriented.…”
Section: Introductionmentioning
confidence: 99%
“…Then, the positive polar decomposition theorem can be used to decompose F into its rotation tensor R and stretch tensor M which is a positive-definite symmetric tensor  F RM (18) Different PS methods used for pose estimation 32,34,37 demonstrated that the rotation matrix Q which satisfies (15) under the constraint condition in (16) is …”
Section: Appendixmentioning
confidence: 99%
“…Therefore, Deutscher and Reid proposed the Annealed Particle Filter (APF) [13], which combines the ideas of the Condensation and the Annealed search so as to improve the tracking results. Corazza et al propose also a custom version of adapted fast simulated annealing [8] for body tracking using as input data a visual hull reconstruction and an a priori model of the subject. Another popular approach for tracking articulated objects is the use of Partitioned Sampling (PS) [27].…”
Section: Optimization Approachesmentioning
confidence: 99%