Order By: Relevance
“…Various types of DC short circuit faults may occur in an MMC-based MTDC power grid, such as pole-to-pole short circuit fault and single-pole-to ground short-circuit fault. Existing research on DC short circuit current calculation mainly focuses on the pole-to-pole short circuit fault, because the pole-to-pole fault current of which is the most serious fault currents of all types of DC fault [13,[34][35][36][40][41][42]. Therefore, the calculation of pole-to-pole short circuit current can provide guidance for parameter design and protection schemes of DC power grids.…”
Section: Short Circuit Current Calculation Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Various types of DC short circuit faults may occur in an MMC-based MTDC power grid, such as pole-to-pole short circuit fault and single-pole-to ground short-circuit fault. Existing research on DC short circuit current calculation mainly focuses on the pole-to-pole short circuit fault, because the pole-to-pole fault current of which is the most serious fault currents of all types of DC fault [13,[34][35][36][40][41][42]. Therefore, the calculation of pole-to-pole short circuit current can provide guidance for parameter design and protection schemes of DC power grids.…”
Section: Short Circuit Current Calculation Methodsmentioning
confidence: 99%
“…The calculation of DC short circuit current calculation considering MMC control in [42] is performed in the frequency domain. The MMC is represented by an AVM and the effect of fault-generated traveling waves (FTWs) is fully considered.…”
Section: Short-circuit Current Calculation Considering MMC Controlmentioning
confidence: 99%
See 1 more Smart Citation
“…On the other hand, ignoring the AC infeed may result in significant deviation between the estimated and the actual results of the fault current. It is found in [17,18] that the computational node voltages without considering the AC infeed significantly deviate from actual values. After a remote DC fault occurs, the simplified model that ignores the AC infeed may cause a capacitor voltage rise of the MMC, which is in contrary to a practical situation.…”
Section: Introductionmentioning
confidence: 99%
“…[17] proposes a general companion circuitbased method to estimate the currents of asymmetric bipolar multi-terminal HVDC grids. The fault calculations based on variable and constant MMC current sources are presented in [18]. The aforementioned papers have contributed to improving the computational accuracy of the fault current.…”
Section: Introductionmentioning