2009
DOI: 10.1016/j.snb.2009.06.034
|View full text |Cite
|
Sign up to set email alerts
|

A miniaturized quantitative polymerase chain reaction system for DNA amplification and detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
29
0

Year Published

2010
2010
2024
2024

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 48 publications
(29 citation statements)
references
References 35 publications
0
29
0
Order By: Relevance
“…In thermal microfluidics systems, different heat sources such as preheated liquids, 19,20 Joule heating, [21][22][23][24][25] microwave heating, [26][27][28] and chemical reactions 29 have been used. Resistive heating (Joule heating) is selected as a heat source in this work to achieve homogeneous heating with a wide operational temperature range, better heat control compared to other methods 30 and for ease of integration onto thin film substrates.…”
Section: Design and Fabrication Of The Thermal Componentsmentioning
confidence: 99%
“…In thermal microfluidics systems, different heat sources such as preheated liquids, 19,20 Joule heating, [21][22][23][24][25] microwave heating, [26][27][28] and chemical reactions 29 have been used. Resistive heating (Joule heating) is selected as a heat source in this work to achieve homogeneous heating with a wide operational temperature range, better heat control compared to other methods 30 and for ease of integration onto thin film substrates.…”
Section: Design and Fabrication Of The Thermal Componentsmentioning
confidence: 99%
“…Nucleic acid analysis generally consists of three major steps: DNA isolation, amplification, and detection. However most researchers have reported LOC systems in which only one or more parts of the nucleic acid analysis steps are integrated 1, [3][4][5][6][7][8][9] . For the commercialization of such bio-chip analysis system, the system management functions such as the data processing and the user interface are also required as well as biochemical processes 1,4-10 .…”
Section: Introductionmentioning
confidence: 99%
“…However, the numbers of thermal cycles are usually not adjustable, and increasing the cycle numbers results in larger device size. Utilization of circular channel loop with circularly arranged heaters was also proposed [14,15]. PCR mixture circulates in the channel loop with three specific temperature zones.…”
Section: Introductionmentioning
confidence: 99%
“…1(c)). Note that since the actuators can be easily driven with DC voltages, the proposed approach eliminates the need of bulky equipments for driving fluid, such as syringe pumps/injectors [15,19], special power supplies [17], or air compressors [16,21]. Figures 3(b) and 3(c) are the schematic illustration of the combined configuration viewed along the xdirection indicated in Fig.…”
Section: Introductionmentioning
confidence: 99%