2015
DOI: 10.1109/tpel.2014.2375919
|View full text |Cite
|
Sign up to set email alerts
|

A Model Predictive Direct Current Control Strategy With Predictive References for MV Grid-Connected Converters With <inline-formula><tex-math notation="LaTeX">$LCL$</tex-math></inline-formula>-Filters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
36
0
2

Year Published

2015
2015
2022
2022

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 81 publications
(38 citation statements)
references
References 35 publications
0
36
0
2
Order By: Relevance
“…Thus, any improvements during the machine design can be optimally exploited by adapting the internal model dynamics in the controller. Another similar approach is to include LCL filters between the inverter and the motor to decrease the high frequency components of the currents; see [26]. These approaches allow operation at lower switching frequencies with low THD at the same time.…”
Section: A Problem Descriptionmentioning
confidence: 99%
See 1 more Smart Citation
“…Thus, any improvements during the machine design can be optimally exploited by adapting the internal model dynamics in the controller. Another similar approach is to include LCL filters between the inverter and the motor to decrease the high frequency components of the currents; see [26]. These approaches allow operation at lower switching frequencies with low THD at the same time.…”
Section: A Problem Descriptionmentioning
confidence: 99%
“…and the matrix M i (u m ) using (27). Now we can decompose the vector in quadratic form (26) using the state definition (17) z 1 = z ph z osc z sw,1:2 z sw,3 z upr 1 .…”
mentioning
confidence: 99%
“…Recently, predictive model-based control (PMC) has been suggested as robust control strategy by [17][18][19] to regulate the AC voltage constant and mitigate harmonics at the PCC. This concept based on prediction current and voltage control techniques for VSI connected to LRC filter is also suggested in [20][21][22][23]. Based on obtained results, the concept based on prediction is more suitable for applications as a standalone system, where the voltage regulation and harmonic mitigation at the PCC, are challenging.…”
Section: Introductionmentioning
confidence: 99%
“…Thus, special attention has to be paid while introducing active damping methods to FCS-MPC applications, such as suggested in [30]- [32]. In this work, online optimized FCS-MPC approaches for grid-connected VSC with LCL filters based on different state feedbacks are presented with the objective to minimize switching losses (via lower switching frequencies) and achieve acceptable current distortion.…”
Section: Introductionmentioning
confidence: 99%