2007
DOI: 10.1002/elps.200600543
|View full text |Cite
|
Sign up to set email alerts
|

A new method for screening and determination of diuretics by on‐line CE‐ESI‐MS

Abstract: A rapid, high-resolution and effective new method for analyzing 12 diuretics by CE-ESI-MS was established in this paper. Ten diuretics (except two neutral compounds) could be fast separated by CE with a DAD at 214 nm with a 20 kV voltage within 6 min, using a 50 microm id and 48.5 cm effective length uncoated fused-silica capillary in a 40 mM ammonium formate buffer (pH 9.40). CE was coupled to the mass spectrometer applying an orthogonal electrospray interface with a triple-tube sheath liquid arrangement. The… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
19
0
1

Year Published

2007
2007
2016
2016

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 30 publications
(20 citation statements)
references
References 25 publications
0
19
0
1
Order By: Relevance
“…In addition, sodium cations and chloride anions may also affect the renal readsorption and excretion of potassium, calcium, magnesium and other ions. Some diuretics increase urinary potassium excretion and can cause hypokalemia in patients treated with these medications for prolonged times [1,2].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition, sodium cations and chloride anions may also affect the renal readsorption and excretion of potassium, calcium, magnesium and other ions. Some diuretics increase urinary potassium excretion and can cause hypokalemia in patients treated with these medications for prolonged times [1,2].…”
Section: Introductionmentioning
confidence: 99%
“…Based on the effect of diuresis, diuretics can also be classified into high-efficiency diuretics (such as loop diuretics), medium-efficiency diuretics (such as thiazides and related compounds) and low-efficiency diuretics (such as potassium-sparing diuretics and carbonic anhydrase inhibitors) [1].…”
Section: Introductionmentioning
confidence: 99%
“…Agilent has produced a CE-MS system (an Agilent 3D CE system coupled to an Agilent 1100 series LC/MSD via an electrospray API interface) that is controlled by only one software program [6][7][8][9][10], whereas other CE-MS systems usually consist of two different instruments joined by an interface. For example, a Beckman and/or Agilent CE coupled with a Thermo Finnigan and/or Bruker MS through an ESI interface [11][12][13] are both operated by two different software programs.…”
Section: Cementioning
confidence: 99%
“…Um avanço no desenho da interface ESI com líquido coaxial para o formato ortogonal, isto é, a 90° com relação ao eixo do espectrô-metro, 52 ou para o formato excêntrico, isto é, alinhado com o eixo do espectrômetro 53 porém não centralizado, introduziu uma maior flexibilidade na escolha dos eletrólitos da CE. O uso de uma interface ortogonal à entrada da amostra (contra-eletrodo) no MS reduz o risco de contaminação ou obstrução da entrada do MS e permite o uso de tampões eletroforéticos moderadamente não voláteis, podendo melhorar a separação dos analitos.…”
Section: Interface Com Líquido Auxiliar Coaxial (Coaxial Sheath Liquid)unclassified