2007
DOI: 10.1016/j.talanta.2006.12.009
|View full text |Cite
|
Sign up to set email alerts
|

A novel application of Onyx™ monolithic column for simultaneous determination of salicylic acid and triamcinolone acetonide by sequential injection chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
9
0

Year Published

2008
2008
2017
2017

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 35 publications
(9 citation statements)
references
References 19 publications
0
9
0
Order By: Relevance
“…Although the use of 50 mm monolithic columns in SIC or multisyringe approaches has been reported previously (Chocholous et al, 2007b;Guzmán-Mar et al, 2011) the present paper is the first to report methanol concentrations as high as 65% (v/v). As methanol generates more pressure than acetonitrile in liquid chromatography, the absence of leakage under the conditions used proves the adequacy of the mechanical configurations made in the system.…”
Section: Separationmentioning
confidence: 59%
See 1 more Smart Citation
“…Although the use of 50 mm monolithic columns in SIC or multisyringe approaches has been reported previously (Chocholous et al, 2007b;Guzmán-Mar et al, 2011) the present paper is the first to report methanol concentrations as high as 65% (v/v). As methanol generates more pressure than acetonitrile in liquid chromatography, the absence of leakage under the conditions used proves the adequacy of the mechanical configurations made in the system.…”
Section: Separationmentioning
confidence: 59%
“…The new configuration of the SIC system allowed the use of a 50 mm long monolithic column (plus a 5 mm guard column) without problems of leakage of mobile phases through the selection or relief valves at a flow rate of 30 μL/s (1.8 mL/min). Although the use of 50 mm monolithic columns in SIC or multi‐syringe approaches has been reported previously (Chocholous et al ., ; Guzmán‐Mar et al ., ) the present paper is the first to report methanol concentrations as high as 65% (v/v). As methanol generates more pressure than acetonitrile in liquid chromatography, the absence of leakage under the conditions used proves the adequacy of the mechanical configurations made in the system.…”
Section: Resultsmentioning
confidence: 99%
“…the solid-phase spectrophotometric (SPS) technique (10), the flow-injection analysis-atomic absorption spectroscopy (FIA-AAS) method (11), CZE (12), solid-phase extraction (SPE)-reversed phase (RP) HPLC-electrospray ionization mass spectrometry (ESI-MS)/fluorescence detection (FLD)/DAD (13), and sequential injection chromatography (SIC) (14) have been reported for the determination of SA, as well as for the simultaneous determination of this chemical with other anti-inflammatory agents. Apart from the methods mentioned, new methods have also been put forward in recent articles.…”
Section: Introductionmentioning
confidence: 99%
“…Some representative pharmaceutical applications of SIC can be found in Table 1 [7,[12][13][14][15][16][17][18][19][20][21][22]. Looking at the methods and the analytical conditions included in Table 1 it is evident that most of the so far reported and published protocols involve separation of simple two/ three component mixtures employing isocratic elution and universal UV detection.…”
mentioning
confidence: 99%
“…Very recently Chocholous et al [19] reported, for the first time, an interesting alternative that could expand the potentials of SIC [26]. This alternative was the incorporation of short HPLC columns based on the novel "fused core" or "core shell" technology.…”
mentioning
confidence: 99%