2022
DOI: 10.11591/eei.v11i1.3274
|View full text |Cite
|
Sign up to set email alerts
|

A novel five-level voltage source inverter interconnected to grid with srf controller for voltage synchronization

Abstract: Power utilization from renewable sources with efficient modules is very vital. Maitaining harmonics below specific standard during grid interconnection is also a major objective. A novel five-level voltage source inverter which is controlled by synchronous reference frame (SRF) controller for grid interconnection and synchronized power injection. The input of the converter is integrated with renewable energy source photovoltaic arrays (PVA) for the injection of renewable power into the grid. For constant volta… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
1
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 17 publications
0
2
0
Order By: Relevance
“…Ants pick their next city based on the pheromone concentration of each route as they go across the countryside. ants pick their transfer routes according to the transfer probability between adjacent ant colonies [21], [22]. As soon as one round of circulation is complete, ants release a little amount of pheromone throughout the paths.…”
Section: Ant Colony Optimization That Been Adjustment 321 the Fundame...mentioning
confidence: 99%
“…Ants pick their next city based on the pheromone concentration of each route as they go across the countryside. ants pick their transfer routes according to the transfer probability between adjacent ant colonies [21], [22]. As soon as one round of circulation is complete, ants release a little amount of pheromone throughout the paths.…”
Section: Ant Colony Optimization That Been Adjustment 321 the Fundame...mentioning
confidence: 99%
“…Moreover, the operation of the converter at large duty cycles increases the losses in parasitic resistances of components. To increase the voltage level, it is essential to design and study new high Isolated converters (DC-DC) use high-frequency transformer which causes a large ripple in the current due to leakage inductance and also spikes in voltage across the switch during turn on and are comparatively bulky and costly [1]- [3]. Use of coupled inductors, they utilize the high reluctance core due to air gap and store the energy in magnetizing inductance of the core and uses turns ratio.…”
Section: Introductionmentioning
confidence: 99%