2009
DOI: 10.1109/tmi.2009.2027436
|View full text |Cite
|
Sign up to set email alerts
|

A Position Sensitive $\gamma $-Ray Scintillator Detector With Enhanced Spatial Resolution, Linearity, and Field of View

Abstract: The performance of a position sensitive gamma-ray scintillator detector (PSD) is described. This PSD is based on a lutetium yttrium oxyorthosilicate (LYSO) crystal read out by a crossed-wire anode position sensitive photomultiplier tube (PSPMT). The main difference with respect to similar existing devices is the individual multi-anode readout (IMAR) approach that is followed here. This method allows to exploit better the intrinsic characteristics of the PSPMT, thus yielding better linearity, improved spatial r… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
13
0

Year Published

2011
2011
2018
2018

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 14 publications
(14 citation statements)
references
References 26 publications
1
13
0
Order By: Relevance
“…This spatial resolution is 5% better than other systems already working with the same aim of SALSA [13] and it is around 30% more than conventional…”
Section: Linearity and Spatial Resolutionmentioning
confidence: 77%
“…This spatial resolution is 5% better than other systems already working with the same aim of SALSA [13] and it is around 30% more than conventional…”
Section: Linearity and Spatial Resolutionmentioning
confidence: 77%
“…It is based on the pulse shape comparison scan (PSCS) principle [31] with a positron annihilation Compton scattering imaging technique [21]. To this aim, a point-like 300 kBq 22 Na positron source is placed between the HPGe detector and a well characterised position sensitive scintillation detector (PSD) [32], which was specifically developed for the present application. The detector is described in detail in Ref.…”
Section: Segmented Detector Description and Experimental Setupmentioning
confidence: 99%
“…The detector is described in detail in Ref. [32] where its performance, in terms of spatial resolution and Peak/Total is also reported. The PSD and the approach followed in the present work are similar to those described in our previous publication [21] for the characterisation of a non-segmented planar HPGe detector.…”
Section: Segmented Detector Description and Experimental Setupmentioning
confidence: 99%
See 2 more Smart Citations