1995
DOI: 10.1080/02772249509358249
|View full text |Cite
|
Sign up to set email alerts
|

A review of microtox test and its applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 94 publications
0
4
0
Order By: Relevance
“…The toxicity results were recorded as effective concentrations (EC 50 ). The Hep-2 cell line was used for the in vitro cytotoxicity assay of each disinfectant (Hao et al 1995). The percentage (%) of the viable cells was determined as follows:…”
Section: Toxicity Assaymentioning
confidence: 99%
“…The toxicity results were recorded as effective concentrations (EC 50 ). The Hep-2 cell line was used for the in vitro cytotoxicity assay of each disinfectant (Hao et al 1995). The percentage (%) of the viable cells was determined as follows:…”
Section: Toxicity Assaymentioning
confidence: 99%
“…These biosensors have been engineered to constitutively express luminescence until metabolically perturbed. Luminescence-based biosensors report on the holistic whole-cell effects of pollutants on cellular metabolism, and therefore the output encompasses many toxic mechanisms such as genotoxicity, cell membrane disruption, or osmotic stress as just a few examples [26]. As they are affected by the individual components of a water sample as well as their combinatorial effects, they are not necessarily suitable for identifying specific individual drivers of toxicity; however, correlations between the concentrations of certain metals and the toxicity values indicated that some metals may have more of a pronounced toxic effect on the biosensors.…”
Section: Biosensors Results and Toxicitymentioning
confidence: 99%
“…They sensitively respond at very low concentrations of toxic pollutants, with resolution over several orders of magnitude. Certain bacteria such as Vibrio fischeri naturally bioluminesce and have been used commercially for the detection of toxicity in freshwater toxicity detection for decades by companies such as Microtox [26,27], however, engineered whole-cell biosensors that are genetically designed for heightened sensitivity and detection of individually toxic components are new to the market. The OMB biosensor testing protocol utilizes positive and negative controls in every assay, allowing comparison between assays and a semiquantitative result proportional to toxicity.…”
Section: Biosensorsmentioning
confidence: 99%
“…To evaluate the hazardous effects of studied MNPs, the toxicity levels of MNPs-disinfectant were measured via a cytotoxicity methods on the Hep-2 cell line with Microtox Analyzer 500 [24,25].…”
Section: Toxicity Performance Assaymentioning
confidence: 99%