2022
DOI: 10.1002/mabi.202200390
|View full text |Cite
|
Sign up to set email alerts
|

A Simple and Low‐Cost Electrochemical Immunosensor for Ultrasensitive Determination of Calreticulin Biomarker in Human Serum

Abstract: An early on time detection of breast cancer significantly affects the treatment process and outcome. Herein, a new label‐free impedimetric biosensor is developed to determine the lowest change in the level of calreticulin (CALR), which is a new biomarker of breast carcinoma. The proposed immunosensor is fabricated by using reduced graphene oxide/amino substituted polypyrrole polymer (rGO‐PPyNH2) nanocomposite modified disposable electrode. The anti‐CALR antibodies are first attached on the rGO‐PPyNH2 nanocompo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 57 publications
0
6
0
Order By: Relevance
“…Nyquist plots typically exhibit two regions along the axis: the first region portrays a semicircular shape, while the second region manifests as a straight line. The semicircular segment observed at high frequencies corresponds to the process governed by electron transfer, whereas the linear portion observed at low frequencies represents the process controlled by diffusion. Figure shows the EIS spectra of both bare CP and poly­(taurine)-CP electrodes in the frequency range of 0.01 to 10,000 Hz in 0.5 M KCl/2.0 mM [Fe­(CN) 6 ] 3–/4– redox probe solution. It was observed that the largest semicircle diameter was obtained on the CP electrode.…”
Section: Results and Discussionmentioning
confidence: 99%
“…Nyquist plots typically exhibit two regions along the axis: the first region portrays a semicircular shape, while the second region manifests as a straight line. The semicircular segment observed at high frequencies corresponds to the process governed by electron transfer, whereas the linear portion observed at low frequencies represents the process controlled by diffusion. Figure shows the EIS spectra of both bare CP and poly­(taurine)-CP electrodes in the frequency range of 0.01 to 10,000 Hz in 0.5 M KCl/2.0 mM [Fe­(CN) 6 ] 3–/4– redox probe solution. It was observed that the largest semicircle diameter was obtained on the CP electrode.…”
Section: Results and Discussionmentioning
confidence: 99%
“…Plant-derived agents such as vincristine and paclitaxel are among the most effective cancer chemotherapeutics [ 110 ]. Interestingly, various chemotherapeutics led to the secretion of danger signals [ 111 ] such as CALR [ 16 ] which showed various tumor-promoting effects in BC and has been recently addressed as a biological marker of BC [ 28 , 29 , 30 , 31 , 32 , 33 , 34 ]. CALR has been reported to be an activator to the NLRP3 pathway [ 36 , 37 , 38 , 39 ].…”
Section: Discussionmentioning
confidence: 99%
“…Interestingly, the exposed CALR has been shown to be subsequently released and detected in the extracellular milieu [ 27 ]. Recently, CALR has been addressed as a promising biological marker of BC and an indicator of BC staging and prognosis [ 28 , 29 , 30 , 31 , 32 ]. In addition, the literature reported that CALR expression was associated with more advanced tumors in a study of 228 BC samples [ 33 ].…”
Section: Introductionmentioning
confidence: 99%
“… 62 The resulting nanoimmunosensor could differentiate between the SSc-related biomarkers from different sets of patients with a limit of detection (LOD) of 0.42 pg mL –1 , which is better than that of the gold standard, ELISA, and gave reproducible results with less than 4% of deviation. Similarly, the group of Aydin et al 201 also fabricated an immunsensor based on reduced graphene oxide/amino-substituted PPy for the detection of calreticulin (CALR), a novel biomarker for breast cancer, via EIS measurements. The resulting sensor exhibited a wide detection range from 0.025 to 75 pg mL –1 , good selectivity in the presence of interferences, a good storage stability, and a LOD of 10.4 fg mL –1 .…”
Section: Conducting Polymersmentioning
confidence: 99%