2005
DOI: 10.1016/j.jneumeth.2005.02.012
|View full text |Cite
|
Sign up to set email alerts
|

A simple technique for localizing consecutive fields for disector pairs in light microscopy: Application to neuron counting in rabbit spinal cord following spinal cord injury

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
38
0

Year Published

2007
2007
2020
2020

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 37 publications
(38 citation statements)
references
References 40 publications
0
38
0
Order By: Relevance
“…For stereological analysis (Gundersen and Jensen, 1987;Chagas et al, 2002, Kaplan et al, 2005 Gundersen and Jensen, (1987). The mean coefficient of variation for each group and the mean coefficient of error for stereological estimation of tissue volumes were observed in an acceptable level.…”
Section: Microscopy Imaging and Stereological Analysesmentioning
confidence: 82%
“…For stereological analysis (Gundersen and Jensen, 1987;Chagas et al, 2002, Kaplan et al, 2005 Gundersen and Jensen, (1987). The mean coefficient of variation for each group and the mean coefficient of error for stereological estimation of tissue volumes were observed in an acceptable level.…”
Section: Microscopy Imaging and Stereological Analysesmentioning
confidence: 82%
“…A test point grid was used to estimate area fraction of the tunica media (TM) including tunica intima, tunica adventitia (TA) and vessel cross sectional area (CSA) of vessel using a modified light microscope (Kaplan et al, 2001;Kaplan et al, 2005). A test point grid, printed on a transparent sheet ( Fig.…”
Section: Stereological Analysismentioning
confidence: 99%
“…A test point grid, printed on a transparent sheet ( Fig. 1), was inserted into the eyepiece and two dial indicators attached to the stage of microscope were used (Kaplan et al, 2001;Kaplan et al, 2005). Systematic random area sampling (200x200µm 2 ) on the section was done by means of dial indicators.…”
Section: Stereological Analysismentioning
confidence: 99%
“…This number is in an acceptable range for stereological analysis. [22,23] Two consecutive sections were mounted on each slide. Photographs of adjacent sections were taken with a digital camera at a magnification of 400×.…”
Section: Numerical Density and Total Number Of Glomerulimentioning
confidence: 99%
“…[23] The mean numerical density of glomeruli [Nv (glomeruli) ] per cm 3 was estimated using the following formula:…”
Section: Numerical Density and Total Number Of Glomerulimentioning
confidence: 99%