1994
DOI: 10.1093/ajh/7.11.989
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy of Single Concentration Estimations of Platelet Angiotensin II Receptor Number

Abstract: Platelet angiotensin II (AngII) receptor number has been suggested as a screening test for pregnancy-induced hypertension. However, markedly different false-positive rates have been reported, perhaps the result of differing methods used. We sought therefore to compare the two methods. Platelet AngII receptor number was determined by saturation analysis with computerized curve fitting and specific binding at a single radioligand concentration. The two methods were compared by correlation and by plotting their d… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

1996
1996
2001
2001

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 0 publications
0
4
0
Order By: Relevance
“…Further purification was performed by gradient reverse-phase HPLC using a C-18 Selectosil column (Phenomenex, Torrance, CA, U.S.A.) as described previously [24]. Further purification was performed by gradient reverse-phase HPLC using a C-18 Selectosil column (Phenomenex, Torrance, CA, U.S.A.) as described previously [24].…”
Section: Radioligand Preparationmentioning
confidence: 99%
See 1 more Smart Citation
“…Further purification was performed by gradient reverse-phase HPLC using a C-18 Selectosil column (Phenomenex, Torrance, CA, U.S.A.) as described previously [24]. Further purification was performed by gradient reverse-phase HPLC using a C-18 Selectosil column (Phenomenex, Torrance, CA, U.S.A.) as described previously [24].…”
Section: Radioligand Preparationmentioning
confidence: 99%
“…Samples were reconstituted with barbitone buffer and assayed by RIA as described previously [24]. After centrifugation at 180 g for 10 min (4 mC), the plasma was applied to and extracted on a Sep-Pak C-18 cartridge using 2 ml of acetonitrile\distilled water\acetic acid (74 : 24 : 4, by vol.).…”
Section: Plasma Ang II Assaymentioning
confidence: 99%
“…Further purification was performed by gradient reverse-phase HPLC using a C-18 Selectosil column (Phenomenex, Torrance, CA, U.S.A.) as described previously [24]. The specific radioactivity of the ligand was determined at 2-week intervals by selfdisplacement in an RIA [24].…”
Section: Radioligand Preparationmentioning
confidence: 99%
“…Specimens were then blown down to dryness under nitrogen and stored at k20 mC until assay. Samples were reconstituted with barbitone buffer and assayed by RIA as described previously [24]. The polyclonal antibody used in this assay cross-reacts with ANG III, but has negligible cross-reactivity with ANG I under assay conditions.…”
Section: Plasma Ang II Assaymentioning
confidence: 99%