2008
DOI: 10.1118/1.2952362
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy of TomoTherapy treatments for superficial target volumes

Abstract: Helical tomotherapy is a technique for delivering intensity modulated radiation therapy treatments using a continuously rotating linac. In this approach, fan beams exiting the linac are dynamically modulated in synchrony with the motion of the gantry and couch. Helical IMRT deliveries have been applied to treating surface lesions, and the purpose of this study was to evaluate the accuracy of dose calculated by the TomoTherapy HiArt treatment planning system for superficial planning target volumes (PTVs). TomoT… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
23
0

Year Published

2009
2009
2018
2018

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 25 publications
(23 citation statements)
references
References 16 publications
0
23
0
Order By: Relevance
“…The accuracy of superficial dose in IMRT cases has been documented by Chung et al (25) for the Pinnacle 3 treatment-planning system and by Mutic and Low (26) for the Peacock treatment-planning system (NOMOS, Sewickley, PA). Similarly, we have documented the accuracy of superficial dose calculated by the TomoTherapy treatment-planning system for the CW geometry in phantom (27)(28)(29) and are currently assessing skin dose in the CW in vivo (30). As in the case of conventional tangent photon beams, the use of a bolus on the CW for all or part of the TomoTherapy treatment can ensure a sufficiently high skin dose and greater accuracy of calculated dose near the patient surface.…”
Section: Discussionmentioning
confidence: 97%
“…The accuracy of superficial dose in IMRT cases has been documented by Chung et al (25) for the Pinnacle 3 treatment-planning system and by Mutic and Low (26) for the Peacock treatment-planning system (NOMOS, Sewickley, PA). Similarly, we have documented the accuracy of superficial dose calculated by the TomoTherapy treatment-planning system for the CW geometry in phantom (27)(28)(29) and are currently assessing skin dose in the CW in vivo (30). As in the case of conventional tangent photon beams, the use of a bolus on the CW for all or part of the TomoTherapy treatment can ensure a sufficiently high skin dose and greater accuracy of calculated dose near the patient surface.…”
Section: Discussionmentioning
confidence: 97%
“…However, bolus has been suggested as desirable for tomotherapy to reduce the effect of daily setup error and potential underdosing of the surface 11 and to correct for shallow depth dose overestimation in the TomoTherapy treatment planning algorithm. 12 Because of the angular dependence of MOSFET dosimeters (3.0%-3.5%), their measurement uncertainties (2%-3%), and other possible setup errors, the estimated accuracy of MOSFET dosimetry is about ±6%. 24 The estimated 12% overestimation of TomoTherapy treatment planning system may include the MOSFET measurement uncertainty.…”
Section: Discussionmentioning
confidence: 99%
“…These doses are substantially less than the predictions of the TPS (full coverage at 3 mm depth, 83% at skin surface), consistent with the documented overestimation of superficial dose by the tomotherapy TPS. [8][9][10][11][12] At a lateral displacement of 2.5 mm, the dose at 3 mm depth remained at 99.2% + 3.3% of the nondisplaced measurement (control). With 5 mm displacement, this ratio remained relatively well preserved at 92.4% + 4%.…”
Section: Resultsmentioning
confidence: 99%
“…10 While the dose at 3 mm depth was relatively unaffected by displacements less than 5 mm, it remains the case that delivered dose at superficial depths is less than that calculated by the current planning system. [9][10][11][12] If the skin is truly at risk, or it is clinically essential that structures within the buildup region for 6 MV photons receive the prescribed dose, despite increased skin toxicity, treatment with bolus or the use of a more accurate algorithm (Monte Carlo) would be required. Our results would be expected to carry over to other rotational IMRT approaches, such as intensity-modulated arc therapy, although that remains a topic of future investigation.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation