Accurate mass and nuclear magnetic resonance identification of bisphenolic can coating migrants and their interference with liquid chromatography/tandem mass spectrometric analysis of bisphenol A

Abstract: Two unknown compounds were previously determined to be potential interferences in liquid chromatography/tandem mass spectrometry (LC/MS/MS) analysis of bisphenol A (BPA) in canned infant formula. Both yielded two identical MS/MS transitions to BPA. The identities of the unknowns were investigated using accurate mass LC/MS, LC/MS/MS, and elemental formula and structures proposed. Exact identities were confirmed through purification or synthesis followed by (1)H and (13)C nuclear magnetic resonance (NMR) experim… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
4
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 30 publications
1
4
0
Order By: Relevance
“…The alternate chromatographic conditions, described above, shortened the BPA retention time and changed the elution order of BPA and known comigrants. 31 Such changes were consistent with the retention and elution profiles previously reported by Petersen et al 32 for bisphenol A diglycidyl ether derivatives. All of the BPA concentrations determined with the Luna C8(2) chromatographic conditions were comparable, within the 95% confidence limit, to those reported using the standard method.…”
Section: ' Results and Discussionsupporting
confidence: 90%
See 1 more Smart Citation
“…The alternate chromatographic conditions, described above, shortened the BPA retention time and changed the elution order of BPA and known comigrants. 31 Such changes were consistent with the retention and elution profiles previously reported by Petersen et al 32 for bisphenol A diglycidyl ether derivatives. All of the BPA concentrations determined with the Luna C8(2) chromatographic conditions were comparable, within the 95% confidence limit, to those reported using the standard method.…”
Section: ' Results and Discussionsupporting
confidence: 90%
“…All of the BPA concentrations determined with the Luna C8(2) chromatographic conditions were comparable, within the 95% confidence limit, to those reported using the standard method. On the basis of the results from the confirmatory quantification method, it is clear that the BPA concentrations reported (Table 3) are not affected by the previously identified comigrating epoxy derivatives 31 and unlikely that they are affected by other coeluting interference.…”
Section: ' Results and Discussionmentioning
confidence: 84%
“…Due to the electronegative properties of phenols, the model BPs were inefficiently ionized under the positive ESI mode. 25 The presence of sulfonyl group in BPS resulted in higher polarity (Table S1) may enhance sensitivity than other nonsulfone bisphenols under positive ESI mode, thus making it the only detectable bisphenol at a concentration of 200 ng/mL. By contrast, DnsCl derivatization could introduce dimethylaminonaphthalene moieties into the phenolic hydroxyl groups and increase the hydrophobicity and protonation, therefore greatly increasing the sensitivity of derivatized BPs by positive ESI ionization via monoprotonation.…”
Section: ■ Results and Discussionmentioning
confidence: 99%
“…For example, the limits of detection (LODs, defined as an instrumental response three times the standard deviation of the noise) of DnsCl-derivatized BPS (d-BPS), BPB (d-BPB), and BPBP (d-TBBPS) were determined to be 0.03, 0.001, and 0.03 ng/mL (at pH = 2.8 for mobile phase A), approximately 6, 60000, and 700 times lower than their optimal LODs without derivatization (0.17, 63, 22 ng/mL), respectively (Table S3). Due to the electronegative properties of phenols, the model BPs were inefficiently ionized under the positive ESI mode . The presence of sulfonyl group in BPS resulted in higher polarity (Table S1) may enhance sensitivity than other nonsulfone bisphenols under positive ESI mode, thus making it the only detectable bisphenol at a concentration of 200 ng/mL.…”
Section: Resultsmentioning
confidence: 99%
“…By comparison of the NMR, MS, and OR data with the references, 14 known compounds were identified as cyclo[Trp‐Gly] (3), [10] cyclo(Trp‐Ana) (4), [11] cyclo‐(Trp‐Ser) (5), [12] glioperazine C (6), [13] cyclo(Ala‐Tyr) (7), indazole (8), [14] 2‐(4‐hydroxyphenyl)‐2‐oxoethanol (9), [15] 2,2‐[bis‐4‐(2,3‐dihydroxypropoxy)phenyl]propane (10), [16] 2‐[4‐(2,3‐dihydroxypropoxy)phenyl]‐2‐[4′‐hydroxyphenyl]propane (11), furan‐2,5‐diyldimethanol (12), [17] 2,3‐butanediol (13), [18] ergosterol (14), [19] 10‐hydroxy‐cis‐12‐octadecenoic acid (15), [20] and oleic acid (16) [21] …”
Section: Resultsmentioning
confidence: 99%