2018
DOI: 10.1016/j.talanta.2017.12.025
|View full text |Cite
|
Sign up to set email alerts
|

Acidity of substituted cathinones studied by capillary electrophoresis using the standard and fast alternative approaches

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 15 publications
(5 citation statements)
references
References 32 publications
0
5
0
Order By: Relevance
“…Although the enantiomers of 4‐MMC have been separated several times , its parent drug (MC) has been selected more rarely , whereas its important isomer (3‐MMC) has not been separated chirally until now. A very close similarity of structures and p K a values of MC, 4‐MMC and 3‐MMC , shown in Fig. , makes their simultaneous enantioseparation not straightforward.…”
Section: The Values Of Validation Parameters Obtained For MC 3‐mmc Amentioning
confidence: 95%
See 1 more Smart Citation
“…Although the enantiomers of 4‐MMC have been separated several times , its parent drug (MC) has been selected more rarely , whereas its important isomer (3‐MMC) has not been separated chirally until now. A very close similarity of structures and p K a values of MC, 4‐MMC and 3‐MMC , shown in Fig. , makes their simultaneous enantioseparation not straightforward.…”
Section: The Values Of Validation Parameters Obtained For MC 3‐mmc Amentioning
confidence: 95%
“…At the beginning, the sample containing MC, 3‐MMC, 4‐MMC (analytes) and 1‐PEA (internal standard) was separated in the phosphate buffers enriched with 10 mM CDs, of the pH value 8.7, close to the p K a values of all three cathinones , see Fig. .…”
Section: The Values Of Validation Parameters Obtained For MC 3‐mmc Amentioning
confidence: 99%
“…CE has been utilized for pK a determination of various compounds mainly in aqueous solutions [28][29][30][31][32][33][34][35] but also in mixed hydro-organic solvents [27,36] and nonaqueous media [37][38][39]. Recently, several innovations in CE determination of pK a have been proposed.…”
Section: Introductionmentioning
confidence: 99%
“…It is a highly automated technique that requires small amounts of compounds and where high purity is not required due to the separation performed inside the capillary. [12][13][14][15][16][17][18][19] The IS-CE method is based on the use of an internal standard (i.e. a compound with known pKa) to measure the pH inside the capillary.…”
Section: Introductionmentioning
confidence: 99%