2016
DOI: 10.1016/j.ptsp.2015.06.001
|View full text |Cite
|
Sign up to set email alerts
|

Activation of the hip adductor muscles varies during a simulated weight-bearing task

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(8 citation statements)
references
References 20 publications
0
8
0
Order By: Relevance
“…After skin preparation, disposable electrodes (Blue Sensor M-00-S, Medicotest, Olstykke, Denmark) were placed along the axis of EO, IO, rectus abdominis (RA), gluteus medius (GMed), and adductor longus (ADD) with a 2 cm inter-electrode distance. The electrodes were placed above and below the rib margin for EO, this was at the lower margin of the eighth rib; 2 cm inferomedial to the superior anterior iliac spine for IO; approximately 3 cm outside the umbilicus for RA [ 24 ]; on the midpoint of the line connecting the ililac crest and the greater trochanter of the femur for GMed [ 25 , 26 ]; and approximately 4 fingerbreadths distal to the pubic tubercle over the bulk of the adductor muscles for ADD [ 27 ]. The method used for measuring IO activity in this study was previously validated and compared with muscle thickness estimated by ultrasound imaging [ 20 ].…”
Section: Methodsmentioning
confidence: 99%
“…After skin preparation, disposable electrodes (Blue Sensor M-00-S, Medicotest, Olstykke, Denmark) were placed along the axis of EO, IO, rectus abdominis (RA), gluteus medius (GMed), and adductor longus (ADD) with a 2 cm inter-electrode distance. The electrodes were placed above and below the rib margin for EO, this was at the lower margin of the eighth rib; 2 cm inferomedial to the superior anterior iliac spine for IO; approximately 3 cm outside the umbilicus for RA [ 24 ]; on the midpoint of the line connecting the ililac crest and the greater trochanter of the femur for GMed [ 25 , 26 ]; and approximately 4 fingerbreadths distal to the pubic tubercle over the bulk of the adductor muscles for ADD [ 27 ]. The method used for measuring IO activity in this study was previously validated and compared with muscle thickness estimated by ultrasound imaging [ 20 ].…”
Section: Methodsmentioning
confidence: 99%
“…The RF was on the mid-point of the line joining the anterior superior iliac spine and the superior patellar pole [27]. The AM was applied midway between the pubic tubercle and the medial femoral epicondyle over the bulk of the adductor muscles [28]. Finally, the BF marker was midway between the ischial tuberosity and tibial epicondyles [29].…”
Section: Landmarks: Anthropometric Points (Ap) and Emg Electrode Atta...mentioning
confidence: 99%
“…Nonetheless, the aforementioned muscle has also been found to play an important role in hip flexion, as well as internal and external rotation on limited flexion angles [12]. A study by Hides et al [3] has found the adductor magnus muscle to be involved to a greater extent in weight-bearing closed chain exercises compared to the adductor longus. Henceforth, the aforementioned types of exercise would not be beneficial in training the latter muscle.…”
Section: Introductionmentioning
confidence: 99%
“…Injuries to the groin, and especially the hip adductor muscles, occur frequently in athletes and contact sports. Extensive knowledge regarding these muscles and their variant anatomy and function is of immense importance to medical professionals and physiotherapists worldwide, as it may help devise a prevention programme (with appropriately directed exercises to strengthen these muscles) or provide adequate treatment upon injuries [3]. Henceforth, the purpose of this case report was to provide a thorough description of bilateral accessory heads of the adductor longus muscle, encountered during a routine cadaver dissection and to provide an up-to-date overview of the clinical implications pertaining to this muscle.…”