2004
DOI: 10.1063/1.1790041
|View full text |Cite
|
Sign up to set email alerts
|

Active beam spectroscopy diagnostics for ITER: Present status (invited)

Abstract: An overview is given of the present design of the active beam spectroscopy diagnostics for the ITER. Present spatial resolution and signal-to-noise indicate that, in principle, all proposed measurements are possible covering the entire plasma minor radius. Calculations show that the mirror based periscopes and the impurity coating of the first mirror affect the signal strength and the polarization characteristics of the measured spectra having an impact in the measurement accuracy. On-line calibration techniqu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0

Year Published

2004
2004
2013
2013

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 23 publications
(14 citation statements)
references
References 3 publications
0
14
0
Order By: Relevance
“…The optical properties and the thickness of the film strongly depend on the experimental conditions, the mirror material and the location of installation in the machine [61]. Experiments have shown that thin films (10 nm) of C-H or Be can strongly modify the reflectance of mirrors as well as its polarization characteristics [268,269]. The latter is of concern in particular for the important MSE diagnostics.…”
Section: Coatingmentioning
confidence: 99%
“…The optical properties and the thickness of the film strongly depend on the experimental conditions, the mirror material and the location of installation in the machine [61]. Experiments have shown that thin films (10 nm) of C-H or Be can strongly modify the reflectance of mirrors as well as its polarization characteristics [268,269]. The latter is of concern in particular for the important MSE diagnostics.…”
Section: Coatingmentioning
confidence: 99%
“…This independence of polarization states is an advantage compared to MSE polarimetry especially in devices with high densities and temperatures, such as ITER. In ITER plasmas plasma facing mirrors are expected to be coated which can change the polarization state of the emitted light significantly [26][27][28] . Figures for the accuracy have been determined by systematic analyses of a well diagnosed plasma discharge at different heating scenarios, from comparisons with equilibrium modelling (CLISTE 2 ) and by comparison with independent measurements of the plasma pressure.…”
Section: Measurement Of the Magnetic Fieldmentioning
confidence: 99%
“…assessment of Motional Stark Effect [6] and Charge Exchange Recombination Spectroscopy [7] for ITER). Yet for turbulence diagnostics, detailed modeling using nonlinear gyrokinetic simulations has not been previously performed as part of a diagnostic design and feasibility study.…”
Section: Introductionmentioning
confidence: 99%