2005
DOI: 10.1016/j.ijrobp.2004.11.041
|View full text |Cite
|
Sign up to set email alerts
|

Acute genitourinary toxicity after high-dose-rate (HDR) brachytherapy combined with hypofractionated external-beam radiation therapy for localized prostate cancer: Correlation between the urethral dose in HDR brachytherapy and the severity of acute genitourinary toxicity

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
19
0

Year Published

2009
2009
2023
2023

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 34 publications
(19 citation statements)
references
References 31 publications
0
19
0
Order By: Relevance
“…The use of less needles might be beneficial in terms of implantation time, cost, and possibly reduce traumarelated morbidity (43). On the other hand, using a very limited amount of catheters is associated with a high urethral dose and can lead to increased acute urinary toxicity (44). In addition, the use of more catheters improves homogeneity and conformity of the dose distribution (38).…”
Section: Discussionmentioning
confidence: 99%
“…The use of less needles might be beneficial in terms of implantation time, cost, and possibly reduce traumarelated morbidity (43). On the other hand, using a very limited amount of catheters is associated with a high urethral dose and can lead to increased acute urinary toxicity (44). In addition, the use of more catheters improves homogeneity and conformity of the dose distribution (38).…”
Section: Discussionmentioning
confidence: 99%
“…In cases in which multiple HDR-BT implants have been performed, it is not usually possible to determine a composite dose-volume histogram of the total treatment. Akimoto et al (25) reported an association between the urethral dose and acute urinary toxicity, with a range of HDR-BT doses of 5 Gy  5 to 9 Gy  2. Ghadjar et al (26) also noted a borderline association between the urethral V 120 and late urinary toxicity using a HDR-BT dose of 7 Gy  3.…”
Section: Discussionmentioning
confidence: 99%
“…Akimoto [1] 70 --V30(u), V80(u), V90(u), V100(u), V110(u), V120(u), V130(u), V150(u) Akimoto [2] 67 --D5(u), D10(u), D20(u), D50(u) Baltas [4] 40 -COIN -Bölling [5] 53 V100, V150, V200, D90, D100 -D max (r), D 2ccm (r), D min (u), D max (u), D1(u) Charra-Brunaud [6] 24 V150 COIN, HI V150(u)…”
Section: Quality Indices Volume and Dose Parameters For Oarsmentioning
confidence: 99%