2014
DOI: 10.1016/j.bios.2013.09.074
|View full text |Cite
|
Sign up to set email alerts
|

Amperometric cholesterol biosensor based on the direct electrochemistry of cholesterol oxidase and catalase on a graphene/ionic liquid-modified glassy carbon electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
34
0
1

Year Published

2015
2015
2021
2021

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 123 publications
(36 citation statements)
references
References 59 publications
1
34
0
1
Order By: Relevance
“…The results indicate that the developed RNA biosensor was excellent and could be used for lncRNA HULC analysis with acceptable reproducibility. Response time is the time required for reaching 95% of the equilibrium signal towards different catalytic material (Choi and Yiu, 2004;Gholivand and Khodadadian, 2014). The biosensor exhibited a rapid response to the changes in 0.8 mM H 2 O 2 concentration in 2 s. But the stable DPV current can be obtained only after 15 s. And the response time of the biosensor was 15 s on going from 0.0 to 0.8 mM H 2 O 2 .…”
Section: Specificity Reproducibility Stability and Reusability Of Tmentioning
confidence: 99%
“…The results indicate that the developed RNA biosensor was excellent and could be used for lncRNA HULC analysis with acceptable reproducibility. Response time is the time required for reaching 95% of the equilibrium signal towards different catalytic material (Choi and Yiu, 2004;Gholivand and Khodadadian, 2014). The biosensor exhibited a rapid response to the changes in 0.8 mM H 2 O 2 concentration in 2 s. But the stable DPV current can be obtained only after 15 s. And the response time of the biosensor was 15 s on going from 0.0 to 0.8 mM H 2 O 2 .…”
Section: Specificity Reproducibility Stability and Reusability Of Tmentioning
confidence: 99%
“…Various analytical strategies for cholesterol assays have been developed that can be subclassified into two groups, including a chemical and an enzymatic method [2][3][4][5]. Currently, the enzymatic method has received greater attention for cholesterol analysis because it provides greater sensitivity and selectivity than the chemical method.…”
Section: Introductionmentioning
confidence: 99%
“…IL, with their high polarity, high selectivity, fast rates, and great biomolecule stability is considered to be suitable media for supporting biocatalytic processes [41,42]. MWCNTs-IL, which combined the advantages of MWCNTs and IL with wide electrochemical window, could ensure that two electrochemical response of cell were detected simultaneously.…”
Section: Preparation Of the Mwcnts-il/gcementioning
confidence: 99%