2005
DOI: 10.1081/jlc-200054869
|View full text |Cite
|
Sign up to set email alerts
|

Amperometric Detection of Estradiol and its Metabolites in Menstrual Women and the Urine of Pregnant Rabbits

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2007
2007
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 25 publications
0
6
0
Order By: Relevance
“…The LOD values obtained for estrone determination using different carbon electrodes and electrochemical techniques are presented in Table 2. From these data, it can be inferred that the performance attained with the CPT BDD is comparatively very good (in the case of the work by Wang and Jseng 29, the LOD value is significantly off the lower limit of the linear range). The LOD values attained simply using the CPT BDD electrode (for both SWV and DPV) are equal or close, respectively, to that reported by Muna et al.…”
Section: Resultsmentioning
confidence: 93%
See 1 more Smart Citation
“…The LOD values obtained for estrone determination using different carbon electrodes and electrochemical techniques are presented in Table 2. From these data, it can be inferred that the performance attained with the CPT BDD is comparatively very good (in the case of the work by Wang and Jseng 29, the LOD value is significantly off the lower limit of the linear range). The LOD values attained simply using the CPT BDD electrode (for both SWV and DPV) are equal or close, respectively, to that reported by Muna et al.…”
Section: Resultsmentioning
confidence: 93%
“…28 determined equine estrogens, including estrone, by RP‐HPLC using electrochemical detection with a carbon fiber electrode; a limit of detection ( LOD ) of 15 µmol L −1 was attained. Wang and Jseng 29 also used a HPLC system with electrochemical detection by a dual thin‐layer GC electrode for the quantitative measurement of five estrogens in human and rabbit urine; despite the range of linearity being 0.18–3.7 µmol L −1 , an astonishingly low LOD value was reported: 1.1 nmol L −1 . Collier et al.…”
Section: Introductionmentioning
confidence: 99%
“…Spectrophotometry [3][4][5][6], liquid chromatography [7,8], gas chromatography [9][10][11][12][13], high-performance liquid chromatography [14][15][16][17], micellar electrokinetic capillary chromatography [18,19], isotope dilution mass spectrometry [20], electrophoresis [21], immunoassay [22,23] and chromatographic separation with amperometry detection [24] have been employed for the determination of ethinylestradiol. Although sensitive and selective, they are time-consuming, expensive and require skilled personnel and therefore are unsuitable for on-line or field monitoring.…”
Section: Introductionmentioning
confidence: 99%
“…Several methods have been employed for the determination of estrogen metabolites in biological fluids and aqueous media, including high‐performance liquid chromatography , liquid chromatography‐mass spectrometry , gas chromatography‐mass spectrometry and flow injection analysis with amperometric detection .…”
Section: Introductionmentioning
confidence: 99%
“…Wang et al. employed HPLC−EC for the detection of estradiol metabolites in urine samples and obtained detection limits less than 1 ng mL −1 for all compounds . Other groups have reported on the detection of estrogenic compounds on chemically functionalized BDD , Ni‐modified glassy carbon and metal porphyrin‐modified graphene oxide .…”
Section: Introductionmentioning
confidence: 99%