1997
DOI: 10.1016/s0956-5663(97)00014-6
|View full text |Cite
|
Sign up to set email alerts
|

Amperometric lactate oxidase catheter for real-time lactate monitoring based on thin film technology

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
20
0

Year Published

1998
1998
2017
2017

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 59 publications
(20 citation statements)
references
References 10 publications
0
20
0
Order By: Relevance
“…More recently, it has been proposed that l-lactate can be produced by astrocytes in the brain and released into the extracellular space to form a pool readily available for neurons in case of high-energy demand (Hu and Wilson, 1997;Pellerin, 2003). Studies support that lactate shuttles between astrocytes al., 1998), and in blood (Gfrerer et al, 1998;Meyerhoff et al, 1993;Pfeiffer et al, 1997). Ultra-low volume microtiter chambers with integrated microelectrodes have been utilized to measure l-lactate from single heart cells (Cai et al, 2002).…”
Section: Introductionmentioning
confidence: 99%
“…More recently, it has been proposed that l-lactate can be produced by astrocytes in the brain and released into the extracellular space to form a pool readily available for neurons in case of high-energy demand (Hu and Wilson, 1997;Pellerin, 2003). Studies support that lactate shuttles between astrocytes al., 1998), and in blood (Gfrerer et al, 1998;Meyerhoff et al, 1993;Pfeiffer et al, 1997). Ultra-low volume microtiter chambers with integrated microelectrodes have been utilized to measure l-lactate from single heart cells (Cai et al, 2002).…”
Section: Introductionmentioning
confidence: 99%
“…Biosensors employed different enzymes have been developed for lactate monitoring. Cytochrome b 2 (Amine et al, 1994;Bartlett and Caruana, 1994), lactate monooxygenase (Mascini et al, 1984), and LOD (Baker and Gough, 1995;Faridnia et al, 1993;Pfeiffer et al, 1997) have been used for this purpose. Bienzyme systems, such as LOD/LDH (Mizutani et al, 1985), cytochrome b 2 /LDH (Schubert et al, 1985) and glutamate pyruvate transaminase/LDH (Lobo-Castannon et al, 1997), have been investigated.…”
Section: Introductionmentioning
confidence: 99%
“…Based on the results obtained, the sensitivity was calculated to be 125.88 Hz/mM-cm 2 and a linear dynamic range of 1-100 mM lactic acid was observed with a linear correlation-regression coefficient of 0.9948. These results are higher in comparison to amperometric lactic acid biosensors previously reported [25,26]. The linear calibration curve was determined using the following equation:…”
Section: Resultsmentioning
confidence: 75%