An Adaptive Droop DC-Bus Voltage Controller for a Grid-Connected Voltage Source Inverter With LCL Filter

Abstract: This paper presents a very fast DC-bus voltage controller for a single-phase grid-connected Voltage Source Inverter (VSI) with an LCL output filter used in renewable energy applications. In single-phase grid-connected inverters, the design of the DC-bus voltage control scheme is very challenging due to the presence of a second harmonic ripple across the DC-bus voltage. The proposed DC-bus voltage control scheme is able to address the difficulties introduced by the second harmonic ripple. The DC-bus voltage con… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
53
0
1

Year Published

2016
2016
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 89 publications
(54 citation statements)
references
References 53 publications
0
53
0
1
Order By: Relevance
“…The structure of a typical adaptive controller is shown in Figure 31. In the literature, some credible research articles and state-of-the-art techniques for adaptive controllers are found in [14,37,53,55,113,[122][123][124][125]. These controllers are applicable for both dynamic as well as static processes.…”
Section: Adaptive Controllersmentioning
confidence: 99%
“…The structure of a typical adaptive controller is shown in Figure 31. In the literature, some credible research articles and state-of-the-art techniques for adaptive controllers are found in [14,37,53,55,113,[122][123][124][125]. These controllers are applicable for both dynamic as well as static processes.…”
Section: Adaptive Controllersmentioning
confidence: 99%
“…In Table 6, regenerated energy and total traction energy change every day, but according to Equation (23), the average energy-saving percentage 畏 (from 18 June 2016 to 30 June 2016) is calculated as high as 11.15%.…”
Section: Coordinated Control Experimentsmentioning
confidence: 99%
“…Several generic control strategies for GSC has been developed [4][5][6][7][8][9][10]. Proper power flow regulation with grid current harmonic rejection using the complementary controller incorporating isolation transformer is discussed in [5].…”
Section: Introductionmentioning
confidence: 99%
“…However, the transient time has not been taken into consideration during sudden change in load conditions. For improving the dynamic response in the dc-link voltage, an adaptive droop controller can be employed in the voltage controlled loop with optimal design of LCL filter on the grid side [9]. Still for simplicity of the decoupled grid power control, estimation of grid parameters is possible by feedback linearizing [10].…”
Section: Introductionmentioning
confidence: 99%