An electrochemical sensor for the detection of p-nitrophenol based on a cyclodextrin-decorated gold nanoparticle–mesoporous carbon hybrid

Abstract: A novel electrochemical sensor based on a cyclodextrin-decorated gold nanoparticle–mesoporous carbon hybrid was constructed for the detection of p-nitrophenol.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
32
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 49 publications
(32 citation statements)
references
References 33 publications
0
32
0
Order By: Relevance
“…The electrochemical reduction peak current of I and II gradually increases with increasing the scan rate from 0.01 to 1.0 Vs −1 . Further, a good linear relationship between reduction peak currents and square root of scan rates ( v 1/2 ) was observed (Figure 11B,D), indicating that the reduction of analytes at the fabricated electrode is a diffusion controlled process 28 . However, the reduction potentials were not changed much while increasing the scan rate (Figure 11A,C,E).…”
Section: Resultsmentioning
confidence: 82%
See 3 more Smart Citations
“…The electrochemical reduction peak current of I and II gradually increases with increasing the scan rate from 0.01 to 1.0 Vs −1 . Further, a good linear relationship between reduction peak currents and square root of scan rates ( v 1/2 ) was observed (Figure 11B,D), indicating that the reduction of analytes at the fabricated electrode is a diffusion controlled process 28 . However, the reduction potentials were not changed much while increasing the scan rate (Figure 11A,C,E).…”
Section: Resultsmentioning
confidence: 82%
“…Further, a good linear relationship between reduction peak currents and square root of scan rates (v 1/2 ) was observed ( Figure 11B,D), indicating that the reduction of analytes at the fabricated electrode is a diffusion controlled process. 28 However, the reduction potentials were not changed much while increasing the scan rate ( Figure 11A,C,E). Normally, the CV results of low scan rate give a small peak current but taking the more measuring time.…”
Section: Effect Of Scan Ratementioning
confidence: 94%
See 2 more Smart Citations
“…Other CDs derivatives for more specific electrochemical applications are represented by succinyl-CDs [17], per-6-deoxy-per-6-(2-carboxy-methyl)thio-β-cyclodextrin (AcSCD) [18], lipoyl-CDs [19] or disulfides bridged two adjacent β-CDs (DB-β-CDs) [20].…”
Section: Chemical Modifications Of Cds For Electrochemical Devicesmentioning