An investigation of the operating characteristics of two PTW diamond detectors in photon and electron beams

Abstract: The dosimetric properties of two PTW Riga diamond detectors type 60003 were studied in high-energy photon and electron therapy beam. Properties under study were current-voltage characteristic, polarization effect, time stability of response, dose response, dose-rate dependence, temperature stability, and beam quality dependence of the sensitivity factor. Differences were shown between the two detectors for most of the previous properties. Also, the observed behavior was, to some extent, different from what was… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
39
1

Year Published

2006
2006
2021
2021

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 71 publications
(45 citation statements)
references
References 13 publications
5
39
1
Order By: Relevance
“…This effect, also observed for D(Ti-Au), indicates the existence of an amount of deep traps quite stable at room temperature. A similar behaviour was reported by some of the present authors (11) with PTW natural diamond detectors for which a daily pre-irradiation dose lower than that initially required to get stability is necessary if irradiation runs are performed on successive days. Also, the dose rate dependence of F56 improved after neutron irradiation.…”
Section: Resultssupporting
confidence: 64%
“…This effect, also observed for D(Ti-Au), indicates the existence of an amount of deep traps quite stable at room temperature. A similar behaviour was reported by some of the present authors (11) with PTW natural diamond detectors for which a daily pre-irradiation dose lower than that initially required to get stability is necessary if irradiation runs are performed on successive days. Also, the dose rate dependence of F56 improved after neutron irradiation.…”
Section: Resultssupporting
confidence: 64%
“…Although in agreement in the overall trends, such a dependence is somewhat higher than the one reported in literature for PTW natural diamonds. 22,41 This is possibly due to the intrinsic fabrication asymmetry of our diamond devices, with few μm thick active layer on top of a ∼400 μm thick substrate. In addition, a significant part of the angular dependence could also arise from the encapsulating materials, their interfaces, the electrode materials, and cables.…”
Section: Iiie Angular Responsementioning
confidence: 99%
“…27,[38][39][40] Results reported in literature for commercial detectors based on natural single crystal diamond indicate a relatively poor intersample reproducibility of the preirradiation dose required to reach a stable response. [21][22][23][24]41 Values ranging from 5 to 15 Gy are reported, depending on the specific impurity concentration into the sample.…”
Section: Iiia Response Stability Response Time and Sensitivity Ofmentioning
confidence: 99%
“…5 Most studies on diamond application for megavoltage electron and photon radiotherapy beam dosimetry have been performed using PTW natural diamond detectors and are reported as comparative investigations with respect to reference detectors, i.e., ionization chambers and silicon diodes. 5,[16][17][18][19][20][21] Although natural diamonds are well assessed in the market, their use is limited by a number of drawbacks, such as high costs, long delivery time due to suitable stones selection, lack of response reproducibility among detectors, and high dose rate dependence, which implies the use of a sampledependent correction factor in dosimetric measurements. On the other hand, spotty results have been reported on synthetic high-pressure high-temperature (HPHT) (Refs.…”
Section: Introductionmentioning
confidence: 99%