An Overview of the Mechanical Integrity of Dental Implants

Abstract: With the growing use of dental implants, the incidence of implants' failures grows. Late treatment complications, after reaching full osseointegration and functionality, include mechanical failures, such as fracture of the implant and its components. Those complications are deemed severe in dentistry, albeit being usually considered as rare, and therefore seldom addressed in the clinical literature. The introduction of dental implants into clinical practice fostered a wealth of research on their biological asp… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
52
1

Year Published

2016
2016
2023
2023

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 70 publications
(54 citation statements)
references
References 38 publications
1
52
1
Order By: Relevance
“…Even the best results in laboratory testing and FEA cannot guarantee clinical success, if the basic biomechanical principles are not taken into consideration during insertion and loading. The leading cause of dental implant loss is considered to be of biological nature but mechanical complications (implant fracture, abutment screw fracture, and abutment fracture) are almost as important [9,10]. Failure can also come from an incorrect prosthetic plan (no metal framework in OD, Cantilever > 15 mm, extreme length of the reconstruction, splinting teeth and implants, ignoring the patient's anatomy and function ( Figure 2) etc.)…”
Section: Background and Aimsmentioning
confidence: 99%
See 1 more Smart Citation
“…Even the best results in laboratory testing and FEA cannot guarantee clinical success, if the basic biomechanical principles are not taken into consideration during insertion and loading. The leading cause of dental implant loss is considered to be of biological nature but mechanical complications (implant fracture, abutment screw fracture, and abutment fracture) are almost as important [9,10]. Failure can also come from an incorrect prosthetic plan (no metal framework in OD, Cantilever > 15 mm, extreme length of the reconstruction, splinting teeth and implants, ignoring the patient's anatomy and function ( Figure 2) etc.)…”
Section: Background and Aimsmentioning
confidence: 99%
“…The most frequently taken into account local parameters concerning the implant are related to diameter, length and angulation, dictated by the bone anatomy. Also, the implant design is taken into consideration, especially when evaluating the bone quality (density) [9,12]. Practitioners are also increasingly aware of the implant surface treatment, with a considerable effect on osseointegration and function [13].…”
Section: Background and Aimsmentioning
confidence: 99%
“…[3,4] At a biological level, osseointegration is defined as close contact between the implant surface and the surrounding bone. [5,6] This is strictly dependent on the surface geometry and topography of the device.…”
Section: Introductionmentioning
confidence: 99%
“…The main issue in implant osseointegration is surface irregularity, that demonstrated to raise osteoblast action in contrast to a smooth surface (7) . Surface roughness of the implant has been improved via different means as machining, plasma spray coating, grit blasting, acid etching, sandblasted and acid etching (SLA), anodizing, and biomimetic coating (8,9) .…”
mentioning