An ultrafast reciprocating probe

Abstract: For tokamak plasma diagnostics, an ultrafast reciprocating probe system driven by magnetic field coils, achieving a maximum velocity of 21 m/s, is introduced. The probes are attached with a driving hoop made of carbon steel and accelerated by three acceleration coils in series, then decelerated by two deceleration coils and buffer springs and return slowly. The coils with a current of about 1 kA generate a magnetic field of about 1 T. This probe system has been tested on the SUNIST (Sino-UNIted Spherical Tokam… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 9 publications
0
4
0
Order By: Relevance
“…The spatial resolution of the HRS system for temperature fluctuation measurement is about 1-2 cm [30]. As shown in figure 1(b), POINT has 11 channels, all of which are parallel to the mid-plane and uniformly distributed from down to up (Z from −42.5 cm to 42.5 cm) in the same poloidal crosssection [31]. The ECE diagnostic has 48 channels, one or two of which covers the pedestal region depending on the pedestal parameters.…”
Section: Methodsmentioning
confidence: 99%
“…The spatial resolution of the HRS system for temperature fluctuation measurement is about 1-2 cm [30]. As shown in figure 1(b), POINT has 11 channels, all of which are parallel to the mid-plane and uniformly distributed from down to up (Z from −42.5 cm to 42.5 cm) in the same poloidal crosssection [31]. The ECE diagnostic has 48 channels, one or two of which covers the pedestal region depending on the pedestal parameters.…”
Section: Methodsmentioning
confidence: 99%
“…AEs in this work are excited by NBI in the presence of strong high-Z impurities. The main equilibrium profiles, such as safety factor, pressure and current, are reconstructed from kinetic-EFIT with magnetic/current constraints from Faraday angles measured by polarimeter-interferometer (POINT) diagnostics [48][49][50]. In addition, pressure is constrained from electron density (n e ) and electron temperature (T e ) is measured by Thomson scattering (TS) diagnostics [51].…”
Section: Experimental Setup and Diagnosticsmentioning
confidence: 99%
“…Moreover, the profiles of electron temperature (T e ) and plasma density (n e ) are measured by Thomson scattering (TS) [36] and reflectometer [37]. The line-averaged electron density (n e ) is measured by either the hydrogen cyanide (HCN) far-infrared interferometer [38] or the polarimeter interferometer [39]. The poloidal or toroidal views of these diagnostics are all shown in figure 1.…”
Section: Main Diagnostics and Divertor Gas-puff Systemmentioning
confidence: 99%